Dock Water Allowance: Loading in Brackish Water

The dock water allowance is how far a ship can submerge its load line in water between fresh and salt: DWA = FWA × (1.025 − ρ) / 0.025, from LL Reg 40(7).

The dock water allowance (DWA) is the amount by which a ship can submerge its summer load line when it loads in water whose density lies between fresh water and salt water, so that it rises to the load line on reaching the sea. It is derived from the fresh water allowance of Regulation 40(7) of the 1988 Load Lines Protocol, as amended by MSC.143(77), which gives FWA = Δ / (40 TPC) cm: DWA = FWA × (1.025 − ρ) / 0.025, where ρ is the dock water density in t/m³. The Protocol prints the FWA formula, not the DWA expression.

The hydrostatics and Bonjean curves article gives the derivation of both from TPC, and the fresh water allowance article covers the load line marks. The full article will cover the hydrometer reading, the Fresh Water and Tropical Fresh Water marks, worked examples, and the limits of the linear relation.