Double-Walled Fuel Piping on Gas-Fuelled Ships

Double-walled and ducted fuel gas piping under IGF Code 9.6 and 9.8: inert-gas annulus or 30 air changes per hour, outer pipe design pressure and zone 1 status.

Double-walled fuel piping is the secondary enclosure the IGF Code requires around fuel gas pipes in a gas-safe machinery space. Paragraph 9.6.1 allows either a double wall whose annulus is pressurized with inert gas above the fuel pressure and alarmed on loss of pressure, or a pipe or duct under mechanical underpressure ventilation of at least 30 air changes per hour, reducible to 10 with automatic nitrogen filling on gas detection.

The outer pipe is designed for at least the inner pipe’s maximum working pressure, or for high-pressure systems the maximum pressure that can build up in the annulus (9.8.1). Ducts around fuel pipes are hazardous zone 1 (12.5.2.6) and carry fixed gas detection (15.8.1.2) with alarm and shutdown at 30 and 60 percent LEL in gas-engine machinery spaces (15.8.7). The full article will cover materials, testing, high-pressure engine connections and the methanol variant in MSC.1/Circ.1621.