Dynamic Positioning (DP): Classes, Vessels, Operations
Dynamic positioning explained: how DP differs from anchoring, the DP1, DP2 and DP3 equipment classes, class notations, DP vessel types and the DPO career path.
Contents17 sections
Dynamic positioning (DP) is the automatic control of a vessel’s own thrusters and propellers to hold a set position and heading, or to follow a track, without anchors or moorings. IMO MSC.1/Circ.1580, approved on 16 June 2017, grades DP vessels into three equipment classes by what a single failure is allowed to do, and the classification societies issue DP notations that map onto those classes.
DP is how a drillship holds over a well in deep water, how a dive support vessel keeps its bell over a work site, and how a shuttle tanker sits astern of a production unit while it loads. No IMO convention makes DP mandatory. The class a job needs comes from the parties’ risk analysis, the coastal state and the industry guidance from IMCA and the Marine Technology Society (MTS) DP Committee. The engineering of the system, its control loop, power plant, sensors and trials, is covered in how a DP system is built; this article covers what DP is, where it is used, which class each operation calls for, and what the casualty record shows.
What counts as dynamic positioning
A vessel is on DP when a control computer, not a mooring line, holds its position. MSC.1/Circ.1580 defines the DP system as comprising, but not limited to, a power system, a thruster system and a DP control system, and treats a DP operation as the automatic control of at least two degrees of freedom in the horizontal plane. A ship holding heading on a joystick, or a vessel lying to its anchors with a thruster trimming the bow, does not meet that description.
The circular covers “vessels and units”, so it reaches ships, drilling units and floating structures alike. It applies to vessels and units constructed on or after 9 June 2017; MSC/Circ.645 of 6 June 1994 may continue to be applied to those built from 1 July 1994 up to that date. Luxembourg Circular CAM 03/2020 states the same split for its flag.
Three things distinguish a DP vessel from a ship that merely has bow and stern thrusters:
- a position reference input, from satellite, acoustic, taut-wire, laser or radar sources, that tells the controller where the vessel is (Circ.1580 calls for at least two references on a class 1 vessel and three on classes 2 and 3);
- a controller that computes the force needed in surge, sway and yaw and divides it among the thrusters;
- a thruster and power arrangement able to deliver that force in any direction, which in practice means azimuth thrusters or tunnel thrusters fed from a diesel-electric plant under a power management system.
A vessel with all three is a DP vessel whether or not it carries a class notation. The ABS Guide for Dynamic Positioning Systems (February 2024) keeps a DPS-0 notation for centralized manual position control with automatic heading control, and DNV keeps DYNPOS(AUTS) and DPS(0). None of those three has an IMO equipment class.
DP compared with anchoring and position mooring
DP replaces mooring lines with thrust, so it trades the fuel and complexity of a running power plant for freedom from the seabed. The choice between the two is made per unit and per field, and a third option, thruster-assisted mooring, sits between them.
Spread mooring and anchoring
A moored unit holds station on lines or chain run to anchors or piles. A spread mooring fixes the heading; a turret mooring lets the unit weathervane about a single point. The line tensions and the restoring force they produce are covered in mooring forces and station keeping, and laying and recovering the spread is the work of the anchor handling tug supply vessel.
The 2009 MODU Code, IMO resolution A.1023(26) of 2 December 2009, sets the anchoring benchmark DP is measured against. Paragraph 4.12.1 asks that anchoring arrangements used as the sole means of position keeping be designed to keep the unit on station in all design conditions, and that “a failure of any single component should not cause progressive failure of the remaining anchoring arrangements”. Paragraph 4.13 then states the whole of the Code’s rule on DP in one sentence:
Dynamic positioning systems used as a sole means of position keeping should provide a level of safety equivalent to that provided for anchoring arrangements.
That is the only DP standard the MODU Code sets. It names no equipment class, and its footnotes still point to MSC/Circ.645 and MSC.1/Circ.738/Rev.1, both since superseded.
Position mooring with thruster assistance
In thruster-assisted mooring, the mooring lines hold the unit and the thrusters reduce line loads or control heading. The unit is moored, not on DP, and the class notations say so.
DNV’s offshore standard DNV-OS-E301, Position Mooring, in its October 2008 edition, assigns POSMOOR, or POSMOOR V where the unit is designed to work in the vicinity of other structures. The letters TA or ATA are added where the system is designed for thruster assistance: TA under a manual remote thrust control system, ATA under an automatic one. The standard’s guidance note says that TA and ATA do “not imply specific requirements regarding number of thrusters or capacity of these”; the thrusters’ effect is folded into the mooring analysis. The same edition makes POSMOOR mandatory for floating production and storage units with main class 1A1 and optional for mobile offshore units.
ABS publishes the equivalent in its Requirements for Position Mooring Systems (July 2022). Its optional notations are TAM, TAM-R (with redundancy, for which a thruster FMEA report is submitted), TAM (Manual) and TAM-PL (Manual) for pre-laid systems. ABS defines thruster-assisted mooring as “a mooring system assisted by onboard thrusters and thruster control systems to provide position keeping for a floating structure”.
TAM means two different things in offshore practice. In ABS class usage it is the thruster-assisted mooring notation. In the MTS DP Operations Guidance it is Task Appropriate Mode, the DP set-up chosen for a less critical activity after a risk assessment. This article writes both out in full.
Choosing between DP and mooring
Water depth, the time spent on each location and the seabed are the usual deciders. A mooring spread has to be laid and recovered at every move, needs a seabed clear of pipelines and wells for its anchors, and grows in length with depth. DP needs none of that, but it runs generators continuously and depends on a power plant, references and a control system whose failure moves the vessel off station.
IMCA M 134, A comparison of moored and dynamically positioned diving support vessels (Rev.0.2, March 2024), is the industry’s document on that trade-off for diving. For production units the class rules lean the other way: the October 2008 edition of DNV-OS-E301 made POSMOOR mandatory for floating production and storage units with main class 1A1, so under that edition an FPSO built to that class is a moored unit even where it carries thrusters for heading control.
How a DP system holds station
A DP system is a closed control loop. Position references and heading, motion and wind sensors measure the vessel’s state; a model-based observer separates the slow drift caused by wind, current and wave drift from wave-frequency motion; a control law computes the force needed; and thrust allocation divides that force among the thrusters at least power. Wind is measured and fed forward; current and wave drift are estimated by the observer as a slowly varying bias.
The redundancy sits in the power plant. Generators and switchboards are split into groups so that a single failure removes one group, and the remaining thrusters must still hold the vessel in the working environment. Whether the bus-ties between groups run open or closed is a design and operating decision covered in DP closed bus-tie operations. The observer and controller are covered in the DP control system, and the reference types in DP position reference systems.
The three IMO equipment classes
The equipment class states what a single failure is allowed to do to station keeping. MSC.1/Circ.1580 section 2.2 defines three classes; MSC/Circ.645 of 1994 set the same three for the earlier fleet.
| Class | Single-failure basis (MSC.1/Circ.1580 para 2.2) | Position references, minimum |
|---|---|---|
| Class 1 (DP1) | Loss of position may occur in the event of a single fault | 2 |
| Class 2 (DP2) | Loss of position should not occur from a single fault in any active component or system, such as generators, thrusters, switchboards and remote-controlled valves; static components are not considered to fail where adequately protected | 3 |
| Class 3 (DP3) | As class 2, plus failure of any static component, and the loss of all components in any one watertight compartment or any one fire sub-division, from fire or flooding | 3, plus 1 connected to the backup DP control system |
Class 3 is the physical-separation class. The redundant groups sit in separate compartments, and the backup DP control system sits in a station separated from the main one by an A-60 class division, with one of each sensor type wired directly to it.
Circ.1580 paragraph 2.4 makes the worst-case failure (WCF) the criterion for the consequence analysis, the online check that the vessel could still hold position after that failure in the present weather. Paragraph 1.2.24 defines the worst-case failure design intent as the specified minimum DP capability to be maintained following the worst-case failure; paragraph 1.2.25 defines the WCF as the single fault with the maximum detrimental effect on DP capability, as determined through the FMEA.
DP equipment class versus station-keeping capability
A class is a redundancy standard, not a capability rating. Two class 2 vessels can lose very different amounts of thrust in their worst-case failure, and so hold very different weather afterwards. The DP capability plot, specified in IMCA M 140 Rev.2 (January 2025), shows the environment the vessel can hold intact and after the worst-case failure, and the consequence analysis checks the same question against live conditions.
Proof that a vessel meets its class comes from the DP FMEA and proving trials, required for classes 2 and 3 by Circ.1580 paragraph 5.1.2, from the five-yearly periodical test, and from annual DP trials under IMCA M 190 Rev.3.2 (M 191 for drilling units). The Administration, or the recognized organization acting for it, then issues the DP Verification Acceptance Document, valid for up to five years with an annual survey within three months of each anniversary.
DP class notations across the classification societies
A DP notation is the class society’s version of the IMO class, assigned on the owner’s request and backed by the society’s own rules. Four classification societies map as follows:
| IMO equipment class | DNV | ABS | Lloyd’s Register | Bureau Veritas |
|---|---|---|---|---|
| No IMO class | DYNPOS(AUTS), DPS(0) | DPS-0 | DP(CM) | DYNAPOS SAM |
| Class 1 | DYNPOS(AUT), DPS(1) | DPS-1 | DP(AM) | DYNAPOS AM/AT |
| Class 2 | DYNPOS(AUTR), DPS(2) | DPS-2 | DP(AA) | DYNAPOS AM/AT R |
| Class 3 | DYNPOS(AUTRO), DPS(3) | DPS-3 | DP(AAA) | DYNAPOS AM/AT RS |
DNV runs the DPS series correlated with MSC/Circ.645 and the DYNPOS series correlated with MSC.1/Circ.1580, with enhanced-reliability and closed bus-tie qualifiers on the DYNPOS series. ABS adds an optional “+” symbol and the EHS and SKP notations in its February 2024 Guide. The Lloyd’s Register marks sit in its Rules for Ships, Part 7, Chapter 4, and the Bureau Veritas row follows the Nautical Institute’s class notation checklist of 28 August 2015. A society-by-society comparison, including NK, KR, RINA, RS and IRS, is kept in DP class notations by classification society, and the general mechanics of notations in classification society.
Capability is graded separately. DNV-ST-0111, Assessment of station keeping capability of dynamic positioning vessels, was first released in July 2016 as DNVGL-ST-0111. It defines Levels 1, 2 and 3 plus site-specific Levels 2-Site and 3-Site: Level 1 is a simplified calculation for ship-shaped single-hull vessels against a Beaufort-scale environment, Level 2 handles any hull shape, and Level 3 uses time-domain simulation. Levels 1 to 3 produce a capability number written “DP Capability-LX (A, B, C, D)”, and the assessment covers the worst-case single failure conditions corresponding to the vessel’s DP class notation. DNV states that Level 1 replaced its ERN* concept; the environmental regularity number (ERN) dates from 1977 and was replaced by ERN* in July 2013.
Vessels and operations that use DP
DP is used wherever a vessel has to hold position or track to metres while something is connected to it: a riser, a diving bell, a loading hose, a gangway, a pipe or a crane load. The industry document sets differ by activity.
Drilling units and drillships
Deepwater drilling was the first DP application. A DP mobile offshore drilling unit, ship-shaped or semi-submersible, holds over a wellhead with a marine riser connected to the blowout preventer on the seabed. A loss of position has to be stopped, or the riser disconnected, before the riser angle reaches its limit, which is why the drilling DP operating guidelines are written around the emergency disconnect system.
The MODU Code adds one drilling-specific DP provision. Paragraph 6.5.2 allows special consideration for selective disconnection or shutdown of the machinery that keeps the DP system running, “in order to preserve the integrity of the well”, on units using DP as the sole means of position keeping. Well-specific operating guidelines (WSOGs) and the MODU appendix to the MTS DP Operations Guidance (Part 2, Appendix 1, Rev3, April 2021) cover the set-up; annual trials follow IMCA M 191 Rev.1.1. Drilling practice beyond station keeping is covered in offshore drilling and wells.
Dive support vessels
On a diving job, the consequence of a position loss falls on people in the water. A DSV supporting saturation diving holds the bell over the work site while divers are connected to it by their umbilicals. IMCA D 010 Rev.4.1 (December 2023), Diving operations from vessels operating in dynamically positioned mode, is the recommended practice, read with the IMCA international code of practice for offshore diving, IMCA D 014 Rev.3.3 (March 2025).
Shuttle tankers and offshore loading
A DP shuttle tanker loads crude over the bow from an FPSO, a storage unit or a loading buoy, holding a set distance astern on a hawser or without one. On the Norwegian continental shelf the operators’ Guideline 140 (Offshore Norge, Rev.01, 30 November 2022) lists DNV DYNPOS(AUTR), or an equivalent ABS, BV or LR notation, among the class notations that “should as a minimum be regarded as mandatory” for offshore loading shuttle tankers. DYNPOS(AUTR) is the DNV class 2 notation. The Nautical Institute runs a separate Shuttle Tanker Scheme for DP operator training.
Floating production units
A production unit can itself be dynamically positioned, or moored with thrusters assisting. MTS Table 4-1 recommends class 2 as the minimum for floating production on DP. Norway’s Havtil guideline recommends class 3 for facilities producing or storing hydrocarbons, and its further guidance says FPSOs and storage units offloading to tank vessels should be equipped with directional control, citing section 63 of the Facilities Regulations.
Pipelay, cable lay and construction
A pipelay vessel tracks slowly along the route while the pipe tension and touchdown point stay within limits, so its DP set point moves rather than stays fixed. Cable-lay vessels do the same for power and telecom cables; IMCA M 264 Rev.0.1 (November 2023) is the code of practice for cable laying in the renewable energy industry. The wider construction spread, from trenching to tie-ins, is covered in subsea and offshore installation.
Offshore wind installation and walk-to-work
Many self-elevating wind turbine installation vessels combine DP with legs, and IMCA M 223 Rev.0.3 (May 2024) gives guidance for positioning DP jack-up vessels on and off the seabed. Service operation vessels hold on DP while a gangway lands technicians on a turbine or platform; IMCA M 254 Rev.1 (August 2025) covers walk-to-work operations. IACS UR E26 Rev.1 names self-propelled units engaged in wind turbine installation, maintenance and repair among the units it covers.
Heavy lift, accommodation and survey
A semi-submersible crane vessel holding on DP during a lift has to absorb the reaction of the load coming off a barge or the seabed; heavy-lift and project cargo work on DP falls under the MTS “lifting” row. A flotel connected to a platform by gangway is a DP accommodation unit. Seismic survey vessels, hydrographic survey ships and ROV support vessels working in open water sit at the low-consequence end of MTS Table 4-1, set out in the next section.
Offshore supply vessels use DP to work alongside an installation inside the 500 m safety zone, the zone a coastal state may set under Article 60(5) of UNCLOS, applied to the continental shelf by Article 80. 182 MSF Rev.4 (May 2022), listed in the IMCA register as International guidelines for the safe operation of dynamically positioned offshore supply vessels, and IMCA M 125 Rev.2.1, the safety interface document for a DP vessel working near an offshore structure, cover that work. Support-vessel practice in general is in offshore support and marine operations.
Which DP class for which operation
No IMO instrument assigns a DP class to an activity. Circ.1580 paragraph 2.1 leaves the choice to the company and the customer, on a risk analysis of the consequence of a loss of position, and otherwise to the Administration or the coastal State. The two documents most often used to set it are the MTS DP Operations Guidance, Part 1 (Rev3, April 2021), Table 4-1, which the US Coast Guard points to as voluntary guidance, and, on the Norwegian continental shelf, the guideline to section 90 of Havtil’s Activities Regulations, Table 1.
| Activity | MTS Table 4-1 minimum recommended class | Havtil guideline, Table 1 (Norway) |
|---|---|---|
| Drilling | 2 | 3 where a DP facility ensures well control; 2 where another facility handles well control; 1 for shallow drilling where hydrocarbons are not expected |
| Diving | 2 | 3 where a loss of position means high risk for divers or the diving bell; 2 for other manned underwater operations |
| Pipelay | 2 | 3 near a facility |
| Lifting | 2 | 3 near a facility |
| Accommodation | 2 | 3 for flotels with gangway connected; 2 for gangway access to simpler facilities |
| Shuttle offtake | 2 | 2 loading from facilities and from unmoored subsea loading; 1 at 2.5 km or more from the facility, else 2, when moored to a subsea loading installation; 1 for buoy loading |
| Floating production | 2 | 3 for facilities producing or storing hydrocarbons |
| ROV support, open water | 1 | not listed |
| ROV support, close to a surface or subsea structure | 2 | not listed |
| Seismic and survey, open water outside 500 m | Class per contract | not listed |
| Well stimulation, logistics (nearest Havtil row; well stimulation may also fall under other well activities, class 2) | 2, or a lesser class with structured risk identification and mitigation | 2 for other safety-zone work where the vessel exceeds the facility’s collision design |
The MTS table is an industry recommendation. Its note adds that a vessel’s DP system should normally be set up to deliver the intent of its class notation, but that after a proper risk assessment it may be set up in Task Appropriate Mode. The Havtil table is a guideline describing one way to meet a binding regulation, and it states that the equipment classes are those of MSC.1/Circ.1580 Chapter 2 and that DP operations should comply with the circular’s Chapter 4.
The Norwegian column sets a higher bar than the MTS minimum. Class 3 for DP drilling with well control, high-risk diving, production units and flotels is a Norwegian guideline position, not the global baseline.
Regional overlays on DP
IMO guidance is the baseline and no convention makes it binding, so DP requirements take force through flag states, coastal states and class rules.
Flag-state application
Flag Administrations give MSC.1/Circ.1580 effect through their own instruments and issue the DPVAD. Luxembourg’s CAM 03/2020 is a published example: it applies Circ.1580 to vessels constructed on or after 9 June 2017, allows MSC/Circ.645 to continue for vessels built from 1 July 1994, and issues the DPVAD for five years with annual verification by the recognized organization. The flag state also sets minimum safe manning, and the Deepwater Horizon investigation found that the unit’s manning certificate had been issued for a self-propelled MODU rather than a DP vessel.
United States
The US has no DP regulation. The Coast Guard published DP guidance for MODUs (77 FR 26562, 4 May 2012) and for other vessels (77 FR 62247, 12 October 2012) conducting Outer Continental Shelf activities as recommended interim voluntary guidance, pointing to the MTS DP Operations Guidance. It proposed binding requirements on 28 November 2014 (79 FR 70943) and withdrew the proposal on 20 May 2022 (87 FR 30849), citing changes in the industry over the preceding seven years.
Norway
Norway regulates DP on its continental shelf through Havtil, the Norwegian Ocean Industry Authority (formerly the Petroleum Safety Authority, PSA). Section 90 of the Activities Regulations, Positioning, requires the responsible party to set requirements for keeping vessels and facilities in position, with criteria for start-up and interruption. Its guideline carries the Table 1 class recommendations above, and Offshore Norge Guideline 140 adds the shuttle tanker notation minimum.
History of dynamic positioning
DP began in offshore drilling in 1961. The MTS DP Committee’s history records CUSS 1 holding station on four thrusters under manual control in March 1961, during Project Mohole, and Shell’s Eureka holding station automatically from May 1961 with a taut-wire reference in about 305 m (1,000 ft) of water. Kongsberg’s own history of the technology describes Eureka (1961) and Caldrill (1964) as using three analog controllers with a taut-wire reference.
The Deep Sea Drilling Project’s Glomar Challenger was launched on 23 March 1968, accepted on 11 August 1968, and made the first re-entry of a deep-ocean drill hole on 14 June 1970 in 3,048 m of water; MTS records it as the first DP vessel to use digital computers. Model-based control followed: Kongsberg’s first DP system went to Seaway Falcon in 1977, and Balchen, Jenssen, Mathisen and Saelid published a Kalman-filter formulation of DP control in Modeling, Identification and Control in 1980.
IMO set the three equipment classes in MSC/Circ.645 of 6 June 1994; the MTS guidance traces the requirement for a DP FMEA to the same circular. MSC.1/Circ.1580, approved on 16 June 2017, replaced it for vessels and units constructed on or after 9 June 2017. The engineering lineage is told in more detail in the DP systems article.
DP operators and the DP watch
A dynamic positioning operator (DPO) is the officer who runs the DP console. The main industry certificate is issued by the Nautical Institute under its Certification and Accreditation Standard, Volume 1 (February 2024): an induction course, at least 60 DP sea time days, a simulator course, a further 60 days and a master’s statement of suitability, for an Unlimited, Limited or Restricted to Unclassed certificate revalidated every five years. A DP sea time day needs at least two hours of DP training.
IMO’s DP operator training guidance is MSC.1/Circ.738/Rev.2 of 16 June 2017, which refers to STCW Code section B-V/f, guidance under the STCW Convention rather than a mandatory standard. IMCA M 117 Rev.3.3 (October 2025) is the code of practice for the training and experience of key DP personnel.
On watch, the DPO works to an activity-specific operating guideline, the ASOG, which tabulates the limits and the action for each status. The MTS guidance uses four statuses: green (normal), blue (advisory), yellow (loss of redundancy with position held) and red (loss of position or control). The vessel’s set-up is either Critical Activity Mode or Task Appropriate Mode, explained in CAM and TAM, and the framework as a whole in the MTS DP Operations Guidance. IMCA M 220 Rev.3 (January 2025) is the guidance on operational activity planning from which the ASOG is built.
Incident reporting and DP casualties
DP failures are tracked through an industry scheme, IMCA’s, with no regulator collecting them worldwide. Two losses investigated by the authorities, Deepwater Horizon (US Coast Guard) and Navion Hispania (Ptil), show how DP redundancy is defeated in service.
IMCA station-keeping event reporting
IMCA’s station-keeping event reporting scheme sorts reports into three categories: a DP incident (a loss of DP capability), a DP undesired event (a loss of redundancy or compromised capability) and a DP observation. For 2024 IMCA received 217 submissions from 169 vessels: 59 incidents, 115 undesired events and 43 observations, and it identified human factors as the largest contributor to position-loss events (IMCA DP Conference Report, 2025). The annual reviews are published as numbered documents, most recently IMCA M 269 for the 2024 events, as listed in the IMCA register of 3 March 2026.
Drive-off and drift-off
A drive-off is a loss of position with the thrusters still running and pushing the vessel away, typically after a bad position or heading input. A drift-off is a loss of position because thrust has been lost, as after a blackout, so the vessel moves with the weather. Neither term is an IMCA reporting category.
Deepwater Horizon, 2010
The Deepwater Horizon was a dynamically positioned mobile offshore drilling unit holding over the Macondo well in Mississippi Canyon Block 252 when it exploded on 20 April 2010. The US Coast Guard’s Report of Investigation, Volume I (MISLE activity 3721503), records that it was built with an ABS DPS-3 dynamic positioning system and eight electric propulsors. To meet DPS-3, ABS required generators and main engines in at least two separate compartments and two separate power management systems.
The report found that the unit “met DPS-3 and IMO MODU Code requirements” but that when explosions damaged Engine Rooms 3 and 6, “the damage was more than the design criteria contemplated”. Ventilation inlets close together meant flammable gas could reach all six engine rooms. The report also records an August 2008 blackout in which the unit lost the ability to actively maintain position “for a period of two minutes”, an event that was not investigated, and a position drop-out on the night when, the senior DPO believed, three positioning antennae on the derrick crown were damaged by fire.
Among its recommendations, the Coast Guard asked the Commandant to work with IMO to amend the MODU Code with more detailed guidance on fire and explosion strategies for units using DP for station keeping, including the emergency power needed to keep station in a flammable gas release. The full casualty is covered in Deepwater Horizon and the Macondo blowout.
Navion Hispania and Njord B, 2006
In 2006, on the Norwegian continental shelf, the DP shuttle tanker Navion Hispania struck the storage ship Njord B at about 1.2 m/s while preparing to offload. A Lloyd’s Register study for the Norwegian safety authority (report PRJ11090745, 10 December 2018) summarizes the investigation: contaminated fuel cost power on all but one propeller. The design intended the initiating failure to cost no more than 50% of available power, but a dormant failure let it affect more equipment than assumed. A long delay before manual control was taken of the remaining propeller and rudder meant the collision was not avoided. The collision energy was calculated at about 55 MJ; damage was material only.
The case shows a hidden common-mode failure defeating a worst-case failure design intent, which is the failure the FMEA and annual trials exist to find. It is covered in Navion Hispania and Njord B.
GNSS dependence and cyber resilience
DP depends on satellite positioning and on networked control computers, and both are single points of exposure that redundancy in thrusters does not cover.
Satellite references share common-mode failures: ionospheric disturbance, blockage under a structure, and deliberate jamming and spoofing. MSC.1/Circ.1580 paragraph 3.4.8.4 answers this in design: where two or more position references are required, they “should not all be of the same type, but based on different principles”. IMO’s performance standard for multi-system receivers, MSC.401(95) of 8 June 2015, applies to receivers installed on or after 31 December 2017. IMCA S 015 Rev.1.1 (June 2024) gives guidelines for GNSS positioning in the oil and gas industry.
On the cyber side, IACS UR E26 Rev.1 (November 2023), Cyber resilience of ships, is applied by IACS societies to ships contracted for construction on or after 1 July 2024. It covers mobile offshore drilling units of 500 GT and upwards and self-propelled mobile offshore units engaged in construction, and lists propulsion, steering, power generation and distribution and navigation among the systems in scope. It does not name DP. Whether a given DP control system falls into a vessel’s asset inventory is decided in the society’s application of the rule; the rule set is covered in IACS UR E26 and the wider subject in maritime cyber security. A failure mode inside the DP network itself, the network storm, is addressed by IMCA M 259 Rev.0.1 (February 2024).
Batteries and spinning reserve on DP vessels
Batteries reduce the number of generators a DP vessel has to keep running. Karlsen and Eriksen of DNV GL set out the reason at the MTS DP Conference of October 2018: traditional DP notations, enhanced-reliability notations excluded, “do not allow for redundancy to be dependent on start of generators”, so the redundancy has to be supplied by machinery already in operation, the spinning reserve.
Using lithium-ion batteries as that reserve lets the vessel run fewer engines, which the same paper links to lower fuel consumption, emissions, running hours and maintenance. Under DNV rules as described in the paper, a vessel that uses batteries as spinning reserve in its DP system must hold the Battery(power) notation, and DNV’s enhanced-reliability DP notations set minimum battery power and energy. IMCA M 250, Introduction to hybrid battery systems for DP vessels (Rev.0.2, April 2024), is the industry’s information guide. The propulsion side is covered in battery-hybrid propulsion.
Limitations
This article states the positions of IMO, the four named classification societies, IMCA, the MTS DP Committee, Havtil, Offshore Norge and the US Coast Guard in the documents and editions named. MSC.1/Circ.1580 is paraphrased from IMCA’s and ABS’s quotations of it and from flag-state application circulars. DNV-OS-E301 is described from its October 2008 edition, which has since been revised, so clause references in the current edition may differ. The current edition of DNV-ST-0111 is not given. UK, Brazilian and Australian coastal-state requirements are not covered. The ABS Requirements for Position Mooring Systems were read in their July 2022 edition from the ABS archive, so a later edition may exist. The Navion Hispania facts come from the 2018 Lloyd’s Register summary commissioned by the Norwegian safety authority, not from the original investigation report.
The MTS and Havtil class tables are recommendations and guidelines. The class used for a specific operation is set by the contract, the coastal state and the risk assessment for that job. Class notation rows for BV come from a 2015 checklist; check the current rule. IMCA documents are listed from the register of 3 March 2026, and many are members-only, so their content is described only where a public source states it.
No figure here describes a specific vessel’s capability. For a real vessel, the FMEA, the capability plots, the DP operations manual, the ASOG for the task and the flag Administration’s requirements govern.
Frequently Asked Questions (FAQs)
What is dynamic positioning?
Dynamic positioning (DP) is the automatic control of a vessel’s own thrusters and propellers to hold a set position and heading, or to follow a track, without anchors or moorings.
IMO MSC.1/Circ.1580 (16 June 2017) treats the DP system as a power system, a thruster system and a DP control system, and grades DP vessels into equipment classes 1, 2 and 3 by what a single failure is allowed to do.
What is the difference between DP1, DP2 and DP3?
Under MSC.1/Circ.1580 paragraph 2.2, a class 1 (DP1) vessel may lose position after a single fault.
A class 2 (DP2) vessel should not lose position from a single fault in any active component or system, such as a generator, thruster, switchboard or remote-controlled valve. A class 3 (DP3) vessel adds the failure of any static component and the loss of everything in any one watertight compartment or fire sub-division, from fire or flooding, so its redundant groups are physically separated.
Is a vessel with a bow thruster a DP vessel?
No. A DP vessel has position references feeding a controller that automatically commands the thrusters in surge, sway and yaw.
A ship that uses a bow thruster for berthing under manual or joystick control has thrusters but not a DP system, and carries no DP equipment class.
Is dynamic positioning mandatory under any IMO convention?
No. MSC.1/Circ.1580 is a circular approved by the Maritime Safety Committee, and no IMO convention makes DP equipment classes mandatory.
They take force through flag-state circulars, class notations, coastal-state regulation such as Norway’s Activities Regulations section 90, whose guideline carries a class table, and contracts.
Which vessels does MSC.1/Circ.1580 apply to?
Vessels and units constructed on or after 9 June 2017.
Vessels built from 1 July 1994 up to that date may continue to apply MSC/Circ.645 of 6 June 1994, as Luxembourg Circular CAM 03/2020 sets out for its flag.
What is the difference between DP and thruster-assisted mooring?
On thruster-assisted mooring the mooring lines hold the unit and the thrusters reduce line loads or control heading; on DP thrust alone holds position.
DNV adds TA (manual) or ATA (automatic) to its POSMOOR notation for thruster assistance (DNV-OS-E301, October 2008 edition), and ABS assigns TAM, TAM-R or TAM (Manual) under its Requirements for Position Mooring Systems (July 2022).
Does TAM mean thruster-assisted mooring or Task Appropriate Mode?
Both, in different documents. ABS uses TAM as a class notation for thruster-assisted mooring.
The MTS DP Operations Guidance uses TAM for Task Appropriate Mode, the DP set-up chosen after a risk assessment for a less critical activity, as opposed to Critical Activity Mode (CAM). Spell the term out when the context could be either.
What does the MODU Code say about dynamic positioning?
The 2009 MODU Code, IMO resolution A.1023(26), says in paragraph 4.13 that DP systems used as the sole means of position keeping should provide a level of safety equivalent to that provided for anchoring arrangements.
It sets no DP equipment class. Paragraph 6.5.2 allows special consideration for selective shutdown of DP machinery to preserve the integrity of the well.
Who decides which DP class a job needs?
MSC.1/Circ.1580 paragraph 2.1 leaves it to the company and the customer, on a risk analysis of the consequence of a loss of position, and otherwise to the Administration or the coastal State.
In practice the MTS DP Operations Guidance Table 4-1 and, in Norway, the Havtil guideline to Activities Regulations section 90 are the usual references.
Which DP class does a drilling unit need?
MTS DP Operations Guidance Part 1 (Rev3, April 2021) Table 4-1 recommends class 2 as the minimum for drilling.
On the Norwegian continental shelf, the Havtil guideline recommends class 3 where a DP facility ensures well control, class 2 where another facility handles well control, and class 1 for shallow drilling where hydrocarbons are not expected.
Which DP class does a dive support vessel need?
MTS Table 4-1 recommends class 2 as the minimum for diving.
Norway’s Havtil guideline recommends class 3 where a loss of position means high risk for divers or the diving bell, for example where the diver lacks unrestricted return to the bell, and class 2 for other manned underwater operations. IMCA D 010 Rev.4.1 (December 2023) is the recommended practice for diving from DP vessels.
Which DP class does a shuttle tanker need?
MTS Table 4-1 recommends class 2 for shuttle offtake.
On the Norwegian continental shelf, Offshore Norge Guideline 140 (Rev.01, 30 November 2022) lists DNV DYNPOS(AUTR) or an ABS, BV or LR equivalent as a minimum, and the Havtil guideline recommends class 2 for loading from facilities and class 1 for buoy loading.
Can a DP1 vessel work inside the 500 m safety zone?
Only on a risk basis. MSC.1/Circ.1580 paragraph 2.1 leaves the class to a risk analysis of the consequence of a loss of position.
MTS Table 4-1 gives class 1 only for open-water ROV support, and lets well stimulation and logistics vessels use a lesser class than 2 where structured risk identification and mitigation are in place. Norway’s Havtil guideline recommends class 2 for other safety-zone work where the vessel is larger than the facility’s collision design.
What DP class do flotels and walk-to-work vessels need?
MTS Table 4-1 recommends class 2 for accommodation.
Havtil’s guideline recommends class 3 for flotels with a gangway connected and class 2 for vessels giving gangway access to simpler facilities. IMCA M 254 Rev.1 (August 2025) is the guidance on walk-to-work operations.
What DP class notations do the classification societies use?
For IMO classes 1, 2 and 3: DNV DYNPOS(AUT), DYNPOS(AUTR) and DYNPOS(AUTRO) (or DPS(1) to DPS(3)); ABS DPS-1, DPS-2 and DPS-3; Lloyd’s Register DP(AM), DP(AA) and DP(AAA); Bureau Veritas DYNAPOS AM/AT, AM/AT R and AM/AT RS.
DNV DYNPOS(AUTS), ABS DPS-0, LR DP(CM) and BV DYNAPOS SAM carry no IMO class.
What is DNV-ST-0111?
DNV’s standard Assessment of station keeping capability of dynamic positioning vessels, first released in July 2016 as DNVGL-ST-0111.
It defines Levels 1, 2 and 3 plus site-specific Levels 2-Site and 3-Site, and Levels 1 to 3 give a capability number written DP Capability-LX (A, B, C, D). DNV states that Level 1 replaced its ERN* concept.
What was the DNV ERN?
The environmental regularity number, a DNV measure of DP station-keeping capability established in 1977 and replaced by ERN* in July 2013.
DNV states that Level 1 of DNV-ST-0111 replaced ERN* in its rules.
What was the first dynamically positioned vessel?
The MTS DP Committee records CUSS 1 holding station on four thrusters under manual control in March 1961 during Project Mohole, and Shell’s Eureka holding station automatically from May 1961 with a taut-wire reference in about 305 m (1,000 ft) of water.
Eureka is the first automatic DP vessel in that record.
When did IMO first define DP equipment classes?
In MSC/Circ.645, Guidelines for Vessels with Dynamic Positioning Systems, of 6 June 1994.
MSC.1/Circ.1580 replaced it for vessels and units constructed on or after 9 June 2017.
How do you become a DP operator?
Through the Nautical Institute scheme (Certification and Accreditation Standard, Volume 1, February 2024): an induction course, at least 60 DP sea time days, a simulator course, a further 60 days and a master’s statement of suitability.
It issues Unlimited, Limited or Restricted to Unclassed certificates, revalidated every five years. A DP sea time day needs at least two hours of DP training.
Does STCW require a DP operator certificate?
No. IMO’s DP operator training guidance is MSC.1/Circ.738/Rev.2 of 16 June 2017, which refers to STCW Code section B-V/f, a guidance section rather than a mandatory standard.
The DP certificate the industry asks for is the Nautical Institute’s, alongside the officer’s STCW certificate of competency.
Who collects DP incident data?
IMCA, through its confidential station-keeping event reporting scheme, which sorts reports into DP incidents, DP undesired events and DP observations.
For 2024 it received 217 submissions from 169 vessels: 59 incidents, 115 undesired events and 43 observations (IMCA DP Conference Report, 2025).
Was Deepwater Horizon a DP rig?
Yes.
The US Coast Guard’s Report of Investigation, Volume I, records that the mobile offshore drilling unit was dynamically positioned over Mississippi Canyon Block 252 on 20 April 2010 and was built with an ABS DPS-3 dynamic positioning system and eight electric propulsors.
Why did DPS-3 redundancy not keep Deepwater Horizon powered?
The Coast Guard report found the unit met DPS-3 and MODU Code requirements, but explosions damaged Engine Rooms 3 and 6, which was more than the design criteria contemplated, and closely spaced ventilation inlets let flammable gas reach all six engine rooms.
Class 3 protects against a single fire or flood, not several at once.
Had Deepwater Horizon lost position before 2010?
Yes.
The Coast Guard report records that in August 2008 the unit blacked out and lost the ability to actively maintain its position for two minutes, and that the event was not investigated.
Can GNSS jamming make a DP vessel lose position?
It can take out every satellite reference at once, which is why MSC.1/Circ.1580 paragraph 3.4.8.4 asks that where two or more position references are required they should not all be of the same type but based on different principles, such as acoustic, taut-wire, laser or radar references alongside satellite ones.
Do the IACS cyber rules apply to DP vessels?
IACS UR E26 Rev.1 (November 2023) applies to ships contracted for construction on or after 1 July 2024, including mobile offshore drilling units of 500 GT and upwards and self-propelled construction units such as wind turbine installation and crane units.
Its scope lists propulsion, steering, power and navigation systems but does not name dynamic positioning.
Why do DP vessels run more generators than the load needs?
Traditional DP notations do not let redundancy depend on starting a generator after a failure, so the reserve has to be machinery already running, the spinning reserve (Karlsen and Eriksen, DNV GL, MTS DP Conference 2018).
Batteries can supply that reserve on DNV-classed vessels holding the Battery(power) notation.
Does the United States regulate dynamic positioning?
Not by regulation.
The US Coast Guard issued voluntary DP guidance for MODUs and other vessels on the Outer Continental Shelf in 2012, pointing to the MTS DP Operations Guidance, proposed binding rules on 28 November 2014 (79 FR 70943) and withdrew them on 20 May 2022 (87 FR 30849).
No question matches. Try a shorter or different word.
Sources
- Luxembourg Maritime Administration Circular CAM 03/2020, Dynamic Positioning Systems. application of MSC.1/Circ.1580 and MSC/Circ.645 maritime.public.lu
- IMCA DP Station Keeping Bulletin 04/18 (November 2018). MSC/Circ.645 and MSC.1/Circ.1580 compared imcaweb.blob.core.windows.net
- IMO Resolution A.1023(26), Code for the Construction and Equipment of Mobile Offshore Drilling Units, 2009, paragraphs 4.12, 4.13 and 6.5.2 imo.org
- Marine Technology Society DP Committee, DP Operations Guidance Part 1, Rev3, April 2021, Table 4-1 dynamic-positioning.com
- Marine Technology Society DP Committee, DP Operations Guidance Part 2, Appendix 1 (DP MODUs), Rev3, April 2021 dynamic-positioning.com
- Havtil, Activities Regulations section 90, Positioning, with guideline Table 1 havtil.no
- Offshore Norge Guideline 140, Recommended guidelines for offshore loading shuttle tankers, Rev.01, 30 November 2022 offshorenorge.no
- ABS Guide for Dynamic Positioning Systems, February 2024 ww2.eagle.org
- ABS Requirements for Position Mooring Systems, July 2022 (TAM, TAM-R, TAM (Manual)) ww2.eagle.org
- DNV Offshore Standard DNV-OS-E301, Position Mooring, October 2008 (POSMOOR, TA, ATA) rules.dnv.com
- DNV, DP capability standard DNVGL-ST-0111. levels, capability numbers and the ERN, 9 August 2017 dnv.com
- DNV, Dynamic Positioning Capability Assessment to DNV-ST-0111 dnv.com
- IMCA Guidance Document Register, 3 March 2026 (D 010, D 014, M 117, M 125, M 134, M 140, M 190, M 191, M 220, M 223, M 250, M 254, M 259, M 264, S 015) imca-int.com
- IMCA DP Conference 2025 Report. DP event reporting statistics for 2024 imca-int.com
- US Coast Guard, Report of Investigation into the Explosion, Fire, Sinking and Loss of Eleven Crew Members Aboard the MODU Deepwater Horizon, Volume I (MISLE 3721503) bsee.gov
- Lloyd's Register for Petroleumstilsynet, report PRJ11090745, risk of vessel operations on the Norwegian shelf, 10 December 2018 (Navion Hispania and Njord B) havtil.no
- IACS UR E26 Rev.1 (November 2023), Cyber resilience of ships classnk.or.jp
- Karlsen and Eriksen (DNV GL), Batteries as power sources in DP systems, MTS DP Conference, October 2018 dynamic-positioning.com
- The Nautical Institute Certification and Accreditation Standard, Volume 1, February 2024 nialexisplatform.org
- IMO MSC.1/Circ.738/Rev.2, Guidelines for Dynamic Positioning System (DP) Operator Training, 16 June 2017 deutsche-flagge.de
- US Coast Guard, withdrawal of the DP notice of proposed rulemaking, 87 FR 30849, 20 May 2022 govinfo.gov
- Marine Technology Society DP Committee, History of DP dynamic-positioning.com
- IMO Resolution MSC.401(95), Performance Standards for Multi-System Shipborne Radionavigation Receivers, adopted 8 June 2015 imo.org
- United Nations Convention on the Law of the Sea 1982, Articles 60 and 80 un.org