FSS Code Chapter 17: Helicopter Facility Foam Firefighting

FSS Code Chapter 17, adopted by MSC.403(96) and in force from 1 January 2020, sets the helideck and helicopter landing area foam appliances on new ships.

FSS Code Chapter 17, Helicopter facility foam firefighting appliances, was added to the FSS Code by resolution MSC.403(96), adopted on 19 May 2016 and in force from 1 January 2020. SOLAS II-2/18.5.1.6 and 18.2.3, added by MSC.404(96) on the same date, apply it to ships constructed on or after 1 January 2020 that have a helideck or a helicopter landing area.

For a helideck it requires at least two fixed foam monitors or a deck-integrated nozzle system plus two hose reels, at 6 l/min per square metre over the D-value area for at least 5 minutes, with discharge within 30 seconds of activation. The full article will cover the definitions, the landing-area provisions, materials, monitor throw and nozzle rules, and how the chapter differs from the older Table 18.1 rates. See marine helicopter operations and helidecks.