Hull Girder Section Modulus

Hull girder section modulus: the neutral axis, moment of inertia, UR S5 members and openings, UR S11 and S7 minimums, shear flow and shear lag explained.

Contents17 sections

The hull girder section modulus is the midship section’s moment of inertia about its neutral axis, divided by its distance to the deck or keel. It converts a vertical bending moment into the bending stress at that point. For ships outside the IACS Common Structural Rules, IACS UR S5 Corr.1 (June 2019) sets how it is calculated. IACS UR S11 Rev.10 and UR S7 Rev.4 set its required and minimum values.

A ship has two moduli, one at the deck and one at the keel, because the neutral axis is not at mid-depth. The rule requirements apply to each modulus. The hull girder strength hub covers the loads, and the still-water bending moment article covers the moment that the loading condition produces.

Beam theory for the hull girder

The hull girder is checked as a beam: plane sections stay plane, and bending stress varies linearly with height from zero at the neutral axis. The section modulus is the property of the beam that connects moment and stress.

The beam relation

For a beam in bending, the stress at a height z above the neutral axis is M (z − zn)/I. At the deck or the keel the distance is largest, and the stress is M/Z. The bending stress card gives the form that CSR BC&OT (1 July 2025) uses in Pt 1 Ch 5 Sec 1, Table 2.

IACS CSR BC&OT (1 July 2025), Pt 1 Ch 5 Sec 1, Table 2

Hull girder bending stress

$$\textcolor{#2a78d6}{\sigma} = \frac{\textcolor{#eb6834}{M}}{\textcolor{#1baf7a}{Z}} \cdot 10^{-3}$$

where

\(\sigma\)hull girder bending stress at the deck or the keelN/mm²
\(M\)vertical bending moment, still-water plus wavekNm
\(Z\)section modulus at the deck or the keelm³

IACS UR S11 Rev.10, S11.5.4.1, writes the same relation for its buckling check: σa = (Ms + Mw)/In × y × 10⁵. There In is in cm⁴ and y in m. UR S11 takes the sagging moment for members above the neutral axis and the hogging moment for members below it.

Where the beam model is approximate

Beam theory assumes that the whole breadth of the deck carries the same stress at the same height. A wide deck with large openings does not do this exactly, and neither does a section where the structure changes suddenly. The rules handle those cases by deducting openings, by shadow lines at non-continuous members, and by the treatment of trunks and coamings described below. IACS UR S11.3.2 also requires buckling checks where the framing system or the hull cross-section changes.

Members counted in the midship section modulus

IACS UR S5 counts “the sectional area of all continuous longitudinal strength members” within 0.4L amidships. A member that is not continuous along the length does not carry the hull girder load and is left out. UR S5 states that it “does not apply to CSR Bulk Carriers and Oil Tankers”.

Figure 1 shows the members of the example double-hull section used on this page.

deckhousebulwarkbilge keelCounted: continuous longitudinalmembers within 0.4L• deck and deck longitudinals• side shell• inner side (longitudinal bulkhead)• inner bottom• bottom shell and bottom longitudinalsNot counted (CSR [1.2.3]):• deckhouses, non-strengthsuperstructures• bulwarks and gutter plates• bilge keels• sniped stiffeners
Figure 1. The hull girder section counts every continuous longitudinal member within 0.4L amidships: on the example ship, the deck, side shells, inner sides, inner bottom, bottom shell and their longitudinals. Deckhouses, bulwarks and bilge keels do not count. The drawing is not to scale.

Members counted and members excluded

CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.1] counts “all continuous longitudinal members below and including the strength deck”. The strength deck is “in general, the uppermost continuous deck” (CSR [1.3.1]). Where a superstructure or deckhouse contributes to longitudinal strength, its deck is the strength deck.

CSR [1.2.3] lists the members that do not contribute:

  • superstructures which do not form a strength deck, and deckhouses
  • vertically corrugated bulkheads, under [1.2.7]
  • bulwarks and gutter plates
  • bilge keels
  • sniped or non-continuous longitudinal stiffeners
  • non-continuous hatch coamings

CSR [1.2.7] adds that longitudinal bulkheads with vertical corrugations “are not effective for hull girder bending, but they are effective for hull girder shear force”. CSR [1.2.5] includes longitudinal stiffeners or girders welded above the strength deck. A non-steel member counts at its steel-equivalent area, scaled by the ratio of its Young’s modulus to 2.06 × 10⁵ N/mm² (CSR [1.2.8]).

Openings and deductions

UR S5 states that large openings, “openings exceeding 2.5 m in length or 1.2 m in breadth”, are “always to be deducted”. It also deducts scallops where scallop welding is applied. CSR [1.2.9] adds circular openings exceeding 0.9 m in diameter, and CSR [1.2.10] deducts manholes as well.

Smaller openings can stay in the calculation within two limits:

  1. Their breadths, or shadow area breadths, in one transverse section reduce the deck or bottom modulus by no more than 3%.
  2. Lightening holes, draining holes and single scallops in longitudinals and girders are no higher than 25% of the web depth. Scallops are no higher than 75 mm.

UR S5 accepts a deduction-free sum of small opening breadths of 0.06 (B − Σb) as equivalent to the 3% test. B is the breadth of the ship and Σb the total breadth of the large openings. UR S5 states that the shadow area “will be obtained by drawing two tangent lines with an opening angle of 30°”. CSR [1.2.11] uses the same 0.06 breadth limit, without the 3% test, and deducts only the excess.

Trunks, hatch coamings and girders

UR S5 includes continuous trunks and longitudinal hatch coamings where “effectively supported by longitudinal bulkheads or deep girders”. The deck modulus is then the moment of inertia divided by yt = y (0.9 + 0.2 x/B), “provided this is greater than the distance to the deck line at side”. The deck and keel modulus card gives the form, with y and x measured to the point that gives the largest yt.

CSR [1.2.4] states that such members “may be included”, and adds primary supporting members as an accepted support. UR S5 considers longitudinal girders between multi-hatchways “by special calculations”. CSR [1.2.6] includes girders between hatchways that longitudinal bulkheads support effectively.

The neutral axis and the moment of inertia

The neutral axis passes through the centroid of the counted section area. The moment of inertia is the second moment of that area about the neutral axis. CSR BC&OT Pt 1 Ch 5 App 1 [1.4] gives both in tabular form.

IACS CSR BC&OT (1 July 2025), Pt 1 Ch 5 App 1 [1.4.2], [1.4.3]

Neutral axis and moment of inertia

$$\textcolor{#2a78d6}{z_{n}} = \frac{S_{y}}{A} = \frac{\sum a_{i}\, z_{i}}{\sum a_{i}}$$
$$\textcolor{#eb6834}{I_{y}} = \textcolor{#1baf7a}{I_{y0}} - z_{n}^{2}\, A$$

where

\(z_{n}\)height of the horizontal neutral axis above the baselinem
\(a_{i}, z_{i}\)area of member i and the height of its centroidm², m
\(S_{y}, A\)first moment of area about the baseline, and total aream³, m²
\(I_{y0}\)second moment of area about the baselinem⁴
\(I_{y}\)moment of inertia about the neutral axism⁴

Worked example: the tabular method

The example section is 32.26 m broad and 20 m deep. Its double bottom and wing tanks are each 2.0 m. Each plate carries its longitudinals smeared into its thickness. The table lists each member with its area a, the height z of its centroid above the baseline, and its own moment of inertia i0.

Membera (m²)z (m)a z (m³)a z² (m⁴)i0 (m⁴)
Deck, 24 mm0.774220.0015.485309.700
Bottom shell, 22 mm0.70970000
Inner bottom, 18 mm0.50872.001.0172.030
Side shells, 2 × 17 mm0.680010.006.80068.0022.67
Inner sides, 2 × 14 mm0.504011.005.54460.9813.61
Total3.176628.846440.7136.27

The calculation runs in five steps:

  1. Divide the first moment by the area. The neutral axis is 28.846 / 3.1766 = 9.081 m above the baseline.
  2. Add the a z² column and the i0 column. The moment of inertia about the baseline is 476.99 m⁴.
  3. Subtract zn² A, which is 9.081² × 3.1766 = 261.94 m⁴. The moment of inertia about the neutral axis is 215.05 m⁴.
  4. Divide by the distances. The deck modulus is 215.05 / 10.919 = 19.69 m³.
  5. The keel modulus is 215.05 / 9.081 = 23.68 m³.

The horizontal plates carry their area at the deck and the bottom, far from the neutral axis, and contribute most of the inertia. The vertical plates add their own inertia and move the neutral axis little, because they are close to symmetric about mid-depth.

IACS UR S5 Corr.1 (June 2019); CSR Pt 1 Ch 5 Sec 1 [1.4]

Deck and keel section modulus

$$\textcolor{#2a78d6}{Z_{D}} = \frac{\textcolor{#1baf7a}{I}}{z_{D} - z_{n}}, \qquad \textcolor{#eb6834}{Z_{B}} = \frac{\textcolor{#1baf7a}{I}}{z_{n}}$$
$$y_{t} = y\,(0.9 + 0.2\, x/B)$$

where

\(Z_{D}\)deck modulus, to the molded deck line at sidem³
\(Z_{B}\)bottom modulus, to the baselinem³
\(I\)moment of inertia about the neutral axism⁴
\(z_{D}, z_{n}\)height of the deck line at side and of the neutral axism
\(y_{t}\)distance used in place of the deck line where a continuous trunk or coaming counts, if it is greaterm
\(y, x\)height of the top of the continuous member above the neutral axis, and its distance from the centerlinem

The stress diagram

Figure 2 shows the bending stress on the example section for a sagging moment of 4,494 MN m. The total is a still-water moment of 2,390 MN m plus the UR S11 wave moment of 2,104 MN m.

neutral axis, 9.08 m above the keel228 N/mm²190 N/mm²Bending stress, saggingcompression abovetension belowI = 215.0 m⁴; deck modulus 19.69 m³; keel modulus 23.68 m³
Figure 2. Bending stress varies linearly with height and is zero at the neutral axis. Under a sagging moment the deck is in compression and the keel in tension, and the deck stress is larger because the deck is farther away. The ship is an example.

The deck is 10.92 m from the neutral axis and the keel 9.08 m. The deck stress is therefore 228 N/mm², and the keel stress 190 N/mm². In a sag the deck is in compression and the keel in tension. In a hog the signs reverse.

The required section modulus under IACS UR S11

IACS UR S11 Rev.10, S11.3.1.1, requires a section modulus of at least |Ms + Mw| / σ × 10³ cm³ within 0.4L amidships. The modulus is calculated by UR S5. The permissible stress σ is 175/k N/mm². Ms and Mw are in kNm.

IACS UR S11 Rev.10 (Dec 2020), S11.3.1.1

Required section modulus

$$\textcolor{#2a78d6}{Z} \ge \frac{\lvert \textcolor{#eb6834}{M_{s}} + \textcolor{#eb6834}{M_{w}} \rvert}{\textcolor{#1baf7a}{\sigma}} \cdot 10^{3}, \qquad \sigma = 175/k$$

where

\(Z\)section modulus at deck and keel, calculated by UR S5, within 0.4L amidshipscm³
\(M_{s}, M_{w}\)still-water and wave bending momentskNm
\(\sigma\)permissible bending stressN/mm²
\(k\)material factor of IACS UR S4: 1.0 for mild steel; use the UR S4 values, not other grades a tool lists

UR S11 applies to steel ships of 90 m in length and greater in unrestricted service, other than CSR bulk carriers and oil tankers. It also excludes container ships under IACS UR S11A. The rule wave bending moment Mw comes from UR S11.2.2.1. The still-water moment Ms comes from the design loading conditions of the loading manual.

For the example ship, the rule length L is 200 m, B 32.26 m and Cb 0.82. The UR S11 coefficient C is 9.75, and the sagging wave moment is 2,104 MN m. With the still-water moment of 2,390 MN m, the total is 4,494 MN m. In mild steel the required modulus is 4,494 × 10³ / 175 × 10³ cm³, or 25.68 m³. The example deck modulus of 19.69 m³ does not meet it.

Higher tensile steel and the factor k

Higher tensile steel raises the permissible stress, so the required modulus falls by the factor k. IACS UR S4 Rev.4 gives k for the higher tensile steels, and UR S7.1 gives 1.0 for ordinary hull structural steel:

Minimum yield stressk
235 N/mm², mild steel1.0
315 N/mm²0.78
355 N/mm²0.72
390 N/mm², with a fatigue assessment0.66
390 N/mm², other cases0.68

Figure 3 applies those grades to the example section. The section does not change. Only the requirement moves.

0102030Section modulus (m³)19.69 m³deck modulus23.68 m³keel modulusUR S11 required 25.68UR S7 minimum 19.12k = 1.00, permissible stress 175/k = 175 N/mm²
Figure 3. Higher tensile steel lowers the required section modulus, because the permissible stress 175/k rises. The section itself and its moduli do not change. The example is not a real ship.Change the steel grade. The section and its moduli stay the same, and the requirements fall with k. AH32 still falls short at the deck, by 0.34 m³. AH36 and AH40 comply.

With AH36 steel the required modulus is 25.68 × 0.72 = 18.49 m³, and the example deck modulus of 19.69 m³ complies. AH32 falls short by 0.34 m³. Higher tensile steel saves weight, but it does not raise stiffness. The minimum moment of inertia, in the next section, carries no factor k.

How far the higher tensile steel extends

IACS UR S11 Rev.10 has no clause on the extent of higher tensile steel. CSR BC&OT Pt 1 Ch 5 Sec 1 [2.4] gives one for CSR ships, shown on the extent card. Paragraph [2.4.2] keeps the steel “continuous over the length of the ship to the location where the longitudinal stress levels are within the allowable range for mild steel structure”.

IACS CSR BC&OT (1 July 2025), Pt 1 Ch 5 Sec 1 [2.4.1]

Vertical extent of higher strength steel

$$\textcolor{#2a78d6}{z_{hts}} \ge \textcolor{#1baf7a}{z_{1}} \left( 1 - \frac{\sigma_{perm}}{\textcolor{#eb6834}{\sigma_{L}}} \right)$$

where

\(z_{hts}\)vertical extent of higher strength steel from the deck line or the baselinem
\(z_{1}\)distance from the neutral axis to the molded deck line or the baselinem
\(\sigma_{L}\)hull girder bending stress at the deck or the bottomN/mm²
\(\sigma_{perm}\)permissible stress of the steel used below that extentN/mm²

Buckling of the members in the modulus

A section modulus is valid only while its members stay effective. IACS UR S11.3.2 requires buckling checks of members that carry longitudinal compressive and shear stresses. It names in particular the regions where the framing system changes or the cross-section changes. Each classification society sets the buckling criteria. UR S11.5 uses net thicknesses with standard deductions for that check. CSR ships of 150 m and above also check hull girder ultimate strength, in Pt 1 Ch 5 Sec 2.

Minimum section modulus and moment of inertia

IACS UR S7 Rev.4 (May 2010) sets a minimum midship section modulus at deck and keel that does not depend on the loading condition. It applies to ships of 90 m to 500 m made of hull structural steel. UR S7 “does not apply to CSR Bulk Carriers and Oil Tankers”.

IACS UR S7 Rev.4 (May 2010), S7.1

Minimum section modulus

$$\textcolor{#2a78d6}{W_{\min}} = \textcolor{#eb6834}{c}\, L^{2} B\, (C_{b} + 0.7)\, \textcolor{#1baf7a}{k}$$
$$c_{n} = 10.75 - \left(\frac{300 - L}{100}\right)^{1.5} \quad (90 \le L \le 300)$$

where

\(W_{\min}\)minimum midship section modulus at deck and keelcm³
\(c\)c_n for new ships; c_s = 0.9 c_n for ships in service
\(k\)material factor of IACS UR S4
\(L, B\)rule length and rule breadthm
\(C_{b}\)rule block coefficient, not less than 0.60

The coefficient c is cn for new ships and cs = 0.9 cn for ships in service. The note to UR S7 defines new ships as “ships in the stage directly after completion”. UR S7 states no age at which the in-service value applies. Cb is “not to be taken less than 0.60”. The cn bands are the same function of L as the UR S11 coefficient C.

For the example ship, cn is 9.75 and the minimum in mild steel is 19.12 m³. With AH36 it is 13.77 m³. UR S11.3.1.1(ii) states that “in any case, the longitudinal strength of the ship is to be in compliance with S7”. The larger of the two requirements therefore governs. For the example, that is UR S11.

Extent along the length and corrosion protection

UR S7.2 requires the scantlings of all continuous longitudinal members to be maintained within 0.4L amidships. In special cases the scantlings can be reduced gradually toward the end of the 0.4L part. UR S7.3 allows certain reductions in tank boundaries with an effective corrosion protection system. Those reductions “should in no case reduce the minimum hull girder section modulus for a new ship by more than 5%”.

Outside 0.4L, IACS UR S11.3.2 leaves the required bending strength to each classification society. It requires checks at the forward end of the engine room and at the forward end of the foremost hold, at least. A ship with large deck openings is also checked at or near the quarter lengths.

Minimum moment of inertia

IACS UR S11 Rev.10, S11.3.1.2, requires a moment of inertia “at the midship point” of at least 3 C L³ B (Cb + 0.7) cm⁴. For the example ship that is 114.7 m⁴, and the section has 215.05 m⁴. The CSR equivalents apply to net properties.

IACS UR S11 Rev.10, S11.3.1.2; CSR Pt 1 Ch 5 Sec 1 [2.3]

Minimum moment of inertia and CSR minimum modulus

$$\textcolor{#2a78d6}{I_{\min}} = 3\, C\, L^{3} B\, (C_{b} + 0.7) \quad (\mathrm{cm}^{4})$$
$$\textcolor{#eb6834}{I_{yR}} = 2.7\, C_{w} L^{3} B\, (C_{B} + 0.7) \cdot 10^{-8}, \qquad \textcolor{#1baf7a}{Z_{R}} = 0.9\, k\, C_{w} L^{2} B\, (C_{B} + 0.7) \cdot 10^{-6}$$

where

\(I_{\min}\)UR S11 minimum moment of inertia at the midship pointcm⁴
\(I_{yR}\)CSR minimum net moment of inertia in the midship partm⁴
\(Z_{R}\)CSR minimum net section modulus at deck and bottomm³
\(C, C_{w}\)UR S11 wave coefficient, and the CSR wave coefficient

Deck openings and the deck modulus

A large deck opening removes deck area far from the neutral axis, so the deck modulus falls more than the keel modulus. Bulk carriers and container ships have such openings over most of their cargo length.

Figure 4 places a centerline opening in the deck of the example section. The full breadth of the opening is deducted, as UR S5 requires for a large opening.

neutral axis 9.08 mSection modulus (m³)19.7deck23.7keelrequired 18.49
Figure 4. A large deck opening is deducted from the section, so the neutral axis moves down and the deck modulus falls faster than the keel modulus. The example is not a real ship.Widen the deck opening. The neutral axis moves down and the deck modulus falls. Above an opening of about 3 m the deck modulus is below the requirement. At 12 m it is 14.76 m³, and the keel modulus has fallen only to 22.18 m³.

With an opening of 12 m, the neutral axis falls from 9.08 m to 7.99 m. The deck modulus falls from 19.69 m³ to 14.76 m³. The keel modulus falls only to 22.18 m³. On the example section the deck modulus is below the AH36 requirement for any opening above about 3 m. For an open ship, torsion is a separate check, and IACS UR S11.3.2 adds checks near the quarter lengths.

Figure 5 applies the same sagging moment of 4,494 MN m to the section with a closed deck and with a 12 m opening. The deck stress rises from 228 N/mm² to 304 N/mm². That is above the AH36 permissible stress of 175/0.72 = 243 N/mm² in UR S11. The keel stress rises only from 190 N/mm² to 203 N/mm².

Closed deckneutral axis 9.08 m above keel228 N/mm²190 N/mm²Zdeck 19.69 m³Zkeel 23.68 m³12 m deck opening, deducted in fullneutral axis 7.99 m above keel243 N/mm²304 N/mm²203 N/mm²Zdeck 14.76 m³Zkeel 22.18 m³compressiontensionpermissible stress 175/k, AH36deck openingZ section modulus
Figure 5. The same moment acts on both sections. The opening removes deck area far from the neutral axis, so the neutral axis moves down, the deck modulus falls, and the deck stress rises more than the keel stress. The ship is an example.

Shear flow and shear stress

The vertical shear force on a section is carried as shear flow in the side shells and longitudinal bulkheads. The shear stress is largest at the neutral axis. The deck and bottom carry little vertical shear. They pass the flow between the sides.

Figure 6 shows the path of the flow on the example double-hull section.

zero at the centerline by symmetryVertical shear force Fside shells: (0.5 − φ)(Fs + Fw)each bulkhead: φ(Fs + Fw)φ given by each classificationsociety (IACS UR S11.4.3)Shear stress is largestat the neutral axis, wherethe first moment S is largest
zero at the centerline by symmetryVertical shear force Fside shells: (0.5 − φ)(Fs + Fw)each bulkhead: φ(Fs + Fw)φ given by each classification society (IACSUR S11.4.3)Shear stress is largest at the neutral axis,where the first moment S is largest
Figure 6. Shear flow carries the vertical shear force around the section. It runs along the deck from the centerline to the sides, down the side shells and the inner sides, and back along the bottom.

The UR S11 shear check

IACS UR S11.4.2 gives the side shell thickness for ships without effective longitudinal bulkheads. The side shell thickness card gives the formula, with a permissible shear stress of 110/k N/mm². S11.4.1 accepts smaller values where a direct stress calculation approved by the society shows a shear stress within 110/k.

IACS UR S11 Rev.10, S11.4.2

Side shell thickness for shear

$$\textcolor{#2a78d6}{t} = \frac{0.5\,\lvert \textcolor{#eb6834}{F_{s}} + \textcolor{#eb6834}{F_{w}} \rvert}{\textcolor{#1baf7a}{\tau}} \cdot \frac{S}{I} \cdot 10^{2}, \qquad \tau = 110/k$$

where

\(t\)minimum side shell thickness, ship without effective longitudinal bulkheadsmm
\(F_{s}, F_{w}\)still-water and wave shear forceskN
\(\tau\)permissible shear stressN/mm²
\(S\)first moment about the neutral axis of the effective members between the level considered and their vertical extremitycm³
\(I\)moment of inertia about the horizontal neutral axiscm⁴

S in the formula is the first moment about the neutral axis of the effective longitudinal members. UR S11.4.2 takes it “between the vertical level at which the shear stress is being determined and the vertical extremity of effective longitudinal members”. S is largest at the neutral axis, so the shear stress is largest there. The 0.5 in the formula gives each of the two side shells half the shear force.

For ships with two effective longitudinal bulkheads, UR S11.4.3 shares the force. Each side shell carries (0.5 − φ)(Fs + Fw) plus a local load term ΔFsh. Each bulkhead carries φ(Fs + Fw) plus ΔFbl. UR S11 defines φ as the “ratio of shear force shared by the longitudinal bulkhead to the total shear force”. It leaves φ and the local terms to each classification society and gives no number.

The CSR shear flow method

CSR BC&OT Pt 1 Ch 5 App 1 computes the shear flow for a unit vertical shear force of 1 N. The flow qv is the sum of a determinate part qD and an indeterminate part qI. The longitudinal stiffeners are included.

IACS CSR BC&OT (1 July 2025), Pt 1 Ch 5 App 1 [1.2.1]

Determinate shear flow

$$\textcolor{#2a78d6}{q_{D}(s)} = -\frac{1}{10^{6}\, \textcolor{#1baf7a}{I_{y}}} \int_{0}^{s} (z - z_{n})\, \textcolor{#eb6834}{t_{n50}}\, \mathrm{d}s$$

where

\(q_{D}(s)\)shear flow for a unit vertical shear force of 1 N, open sectionN/mm
\(I_{y}\)net moment of inertia about the horizontal neutral axism⁴
\(t_{n50}\)net plate thickness, gross less 0.5 t_cmm
\(s, z, z_{n}\)distance along the plating from the slit, height of the point, height of the neutral axism

The method treats an open section first. Closed cells “are to be cut with virtual slits”, and the indeterminate flow “can be considered as a constant value within the same closed cell” (App 1 [1.2.3] and [1.3.1]). CSR Pt 1 Ch 5 Sec 1 [3.2.1] then finds the shear capacity QR. It uses the permissible shear stress, the net thickness and the unit flow of each plate. The CSR checks shear “along the full length of the hull girder”.

Shear capacity against the shear force

CSR Pt 1 Ch 5 Sec 1 [3.3.1] compares the still-water shear force with the capacity QR. At sea the check is Qsw ≤ QR − fβ Qwv. In harbor it is Qsw-p ≤ QR, and in the flooded case Qsw-f ≤ QR − Qwv. Under UR S11.4.2(ii), each classification society can correct the shear force for loads carried directly to transverse bulkheads.

Effective breadth and shear lag

Effective breadth is the width of plating that works with a stiffener or girder as its flange. Shear lag is the reason it is less than the full width. In-plane shear deforms the plating, so the stress at points far from the web lags behind the stress next to it.

What the rules state

CSR BC&OT Pt 1 Ch 3 Sec 7 [1.3] gives the effective breadth of attached plating for local members. For a stiffener with plating on both sides, the effective breadth is the lesser of 200ℓ and the spacing s. For a stiffener at an opening it is the lesser of 100ℓ and 0.5 s. Where the net plate thickness is under 8 mm, the breadth is not to exceed 600 mm. Primary supporting members have their own formula in [1.3.2].

UR S5, UR S11 and CSR Pt 1 Ch 5 Sec 1 give no shear lag reduction factor for the hull girder as a whole. They handle the effect in other ways:

  • UR S5 deducts large openings in full and draws shadow areas at 30° behind small openings.
  • CSR Pt 1 Ch 5 Sec 1 [1.2.13] draws shadow lines at 15° to the ship’s axis behind non-continuous decks and longitudinal bulkheads. The area in the shadow is not effective.
  • Where trunks or coamings count, UR S5 and CSR [1.4.3] measure the deck modulus to yt = y (0.9 + 0.2 x/B). The height y is measured to the top of the continuous member. The value yt is used only where it is greater than the distance to the deck line at side.

The section modulus in the CSR yielding check

A CSR ship checks its hull girder stress against permissible values along the full length, not only within 0.4L. CSR BC&OT Pt 1 Ch 5 Sec 1 [2.2.1] assesses the stress “for both hogging and sagging conditions, along the full length of the hull girder, from AE to FE”. The section modulus also fixes the first-yield moment MY; the ultimate bending capacity is a separate check.

The stress in each design condition

CSR Pt 1 Ch 5 Sec 1, Table 2, gives the hull girder stress for each condition. The moment is in kNm, the modulus in m³ and the stress in N/mm².

ConditionHull girder stress, CSR Table 2
Seagoing(Msw + fβ Mwv) / Z × 10⁻³
Harbor and sheltered waterMsw-p / Z × 10⁻³
Flooded, bulk carriers of load line length 150 m or above(Msw-f + Mwv) / Z × 10⁻³

The factor fβ is 1.05 for seagoing conditions. It is 1.0 for ballast water exchange at sea, for harbor and sheltered water, and for the accidental flooded case. Z is the net modulus at the deck, the bottom or any point, as CSR [1.4] defines it.

The permissible stresses

CSR Pt 1 Ch 5 Sec 1, Table 1, sets the permissible stress. At sea it is 190/k N/mm² from 0.3L to 0.7L and 140/k N/mm² at the ends. In harbor and sheltered water it is 143/k N/mm² and 105/k N/mm². The values in the 1 July 2025 edition are the same as in the 2022 text. The still-water article shows how the harbor and seagoing envelopes are set.

The CSR permissible stress of 190/k N/mm², from 0.3L to 0.7L, is higher than the 175/k N/mm² of UR S11. The two are not comparable directly. The CSR applies its value to a net modulus with its own wave moment. UR S11 applies 175/k to the modulus calculated under UR S5, which states no corrosion deduction.

The CSR equivalent deck line

CSR [1.4.3] takes the deck modulus to the equivalent deck line VD. In the simple case, VD is the distance from the neutral axis to the deck at side. That case applies where no member of [1.2.4] or [1.2.5] lies above a line. The line runs from the strength deck at side to a point (zD − zn)/0.9 above the neutral axis at the centerline. Otherwise VD = (zT − zn)(0.9 + 0.2 yT/B), and not less than the distance to the deck at side. That is the same form as the UR S5 rule for trunks and coamings.

Net scantlings and corrosion

A CSR ship calculates its hull girder properties on net scantlings, at the gross offered thickness less 0.5 tc. For a non-CSR ship, UR S5 states no corrosion deduction.

CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.2] sets the net basis for the yielding check. The buckling check uses the gross thickness less the full tc. The corrosion addition tc comes from Ch 3 Sec 3, and its value depends on the compartment. The derivation of tc, and the renewal thickness it sets for the ship in service, are in corrosion margins and renewal thickness. The minimum net modulus of CSR [2.3.2] therefore applies to a section that has already lost half its corrosion margin.

Section modulus in service

Corrosion reduces the section modulus of a ship in service. The in-service evaluation rules of IACS set when the modulus is evaluated and the value it has to reach. The checks apply at the special survey, with the measured, renewed and reinforced thicknesses.

Oil tankers under UR Z10.1 and UR Z10.4

IACS UR Z10.1 Rev.25 (February 2023) applies to oil tankers of 130 m in length and upwards. The length is as defined in the International Convention on Load Lines. Their longitudinal strength is evaluated at the special survey after the ship reaches 10 years of age, by Annex III. UR Z10.4 Rev.18 has the same rule, in 9.1.1.1, for double hull oil tankers. Rev.25 of Z10.1 applies to surveys commenced on or after 1 July 2024.

Annex III, 2.1.2, compares the deck and bottom flange areas with the as-built areas. UR Z10.1, 8.1.1.2, reports the final result in the Executive Hull Summary. The deck flange is the deck plating with its longitudinals, and the bottom flange is the bottom shell with its longitudinals. If either has lost more than 10% of its as-built area, one of two measures is taken:

  1. renew or reinforce the flanges to at least 90% of the as-built area, or
  2. calculate the actual section modulus by the method of Annex III, Appendix 1, which repeats UR S5.

For a ship built on or after 1 July 2002, Annex III, 2.2.1.1, requires the actual modulus to meet the class society’s diminution limits. The Annex III footnote states that the actual modulus “is not to be less than 90% of the required section modulus for new buildings” under S7 or S11, whichever is greater, with C = 1.0 cn. Older ships meet a floor of Zmc = 0.9 cn L² B (Cb + 0.7) k, from Appendix 2.

Figure 7 applies the Annex III test of UR Z10.1 or Z10.4 to the example section, built of AH36 steel. The example ship is a notional non-CSR ship.

14161820220102030Loss of deck and bottom flange area (%)Deck modulus (m³)up to 10%: no calculationover 10%: renew or calculate90% of new-building requirement 16.64as built 19.69 m³10% loss 18.20 m³20.5% loss reaches 90%
Figure 7. Corrosion of the deck and bottom flanges reduces the section modulus in service. Beyond the trigger loss the actual modulus is calculated, and below the 90% line the flanges are renewed or reinforced. The ship is an example.

On the example, the new-building requirement is 18.49 m³, so the 90% line is 16.64 m³. Up to 10% flange loss no calculation is needed. Above about 20.5% the actual modulus is below 16.64 m³, and the flanges have to be renewed or reinforced.

Annex III, Appendix 3, sets the sampling. Longitudinal strength is evaluated within 0.4L amidships, and within 0.5L for adjacent tanks that extend beyond it. Within 0.1D of the deck and the bottom, every longitudinal and girder is measured on the web and face plate. The thickness measurement and close-up survey program of the Enhanced Survey Programme supplies the data.

Sampling and reporting

Appendix 3 also extends the sampling where a section is deficient. Every tank within 0.5L is then measured. After a repair, one more section is measured forward and aft of each repaired area. The report form, Table IX(v) of UR Z10.1, has three parts:

  1. the 10% flange area test, for all ships
  2. the modulus test for ships built on or after 1 July 2002
  3. the Zmc test for ships built before 1 July 2002

Bulk carriers and CSR ships

IACS UR Z10.2 Rev.37 (February 2023), 9.1.1.1, applies a longitudinal strength evaluation to CSR bulk carriers. It applies after the ship reaches 15 years of age, or at special survey No.3 if that is earlier, by the CSR criteria. UR Z10.2, 9.1.1.1, is written for CSR bulk carriers.

CSR BC&OT Pt 1 Ch 13 Sec 2 [2.2] applies to ships over 10 years of age. It requires the current modulus at deck and bottom to be at least 90% of the modulus at the gross offered thickness. Alternatively, the deck and bottom zone areas are at least 90% of their gross values. The calculation is not needed where every reduction is less than 10% in the deck and bottom zones. In the neutral axis zone the limit is 0.5 tc.

Three different 90% figures

The figure 90% appears in three rules with three meanings:

RuleWhat 90% refers to
IACS UR S7 Rev.4, S7.1cs = 0.9 cn, the in-service minimum for non-CSR ships
IACS UR Z10.1 and Z10.4, Annex IIIActual modulus against the new-building S7 or S11 requirement, and flange area against as-built
CSR BC&OT Pt 1 Ch 13 Sec 2 [2.2.2]Current modulus against the modulus at the gross offered thickness

A survey report states which rule it applied. The three are not interchangeable.

Section modulus by ship type

Each ship type meets the section modulus requirement in its own way. Its deck openings, its framing and its rule set decide how. The rule set comes first, because UR S5, S7 and S11 do not apply to CSR ships.

Ship typeRule set for the modulusFeature that governs the section
Double hull oil tanker, 150 m and above, contracted from 1 July 2015CSR BC&OTContinuous deck with no large openings; net properties
Bulk carrier, 90 m and above, contracted from 1 July 2015CSR BC&OTHatch openings deducted; topside and hopper tanks
Container ship, 90 m and above, contracted from 1 July 2016IACS UR S11AWide deck openings; torsion and horizontal bending
General cargo ship, 90 m and aboveUR S5, S7 and S11Hatch openings; trunks and coamings under UR S5
Chemical tanker or gas carrier, 90 m and aboveUR S5, S7 and S11Category I ship under UR S1

The CSR applicability is from CSR Pt 1 Ch 1 Sec 1. It covers double hull oil tankers of 150 m and above and bulk carriers of 90 m and above. Both are contracted on or after 1 July 2015, in unrestricted service. The UR S11A date is from UR S11A (June 2015).

Tankers

A double hull oil tanker has a continuous strength deck and longitudinal bulkheads that carry both bending and shear. Its in-service modulus is evaluated under UR Z10.4 from 10 years of age, for ships of 130 m and upwards. A chemical tanker outside the CSR uses UR S5, S7 and S11.

Bulk carriers and general cargo ships

A bulk carrier’s hatch openings are large openings under UR S5 and CSR [1.2.9]. The deck strips beside the hatches and the topside tanks therefore carry the deck flange. UR S5 considers girders between multi-hatchways by special calculation. A general cargo ship with continuous coamings can count them under UR S5 when longitudinal bulkheads or deep girders support them effectively.

Container ships

A container ship’s deck is mostly opening, so its hull girder is an open section. IACS UR S11A applies to ships contracted on or after 1 July 2016. For ships wider than 32.26 m it adds wave torsion, horizontal bending and static cargo torque. The UR S11A article covers those checks. The 2013 loss of the MOL Comfort has its own article.

Common errors in section modulus calculations

Most section modulus errors come from counting a member that does not carry the load, or from mixing units and rule regimes. Each error below has its source in the rules.

  • A large opening left in. UR S5 and CSR [1.2.10] always deduct it.
  • A corrugated longitudinal bulkhead counted for bending. CSR [1.2.7] counts it for shear only.
  • The deck modulus measured to the wrong point. UR S5 measures to the molded deck line at side, or to yt for a counted trunk or coaming.
  • cm³ against m³. UR S11 and UR S7 give the modulus in cm³, and the CSR gives it in m³. One cubic meter is 10⁶ cm³.
  • UR S11 values applied to a CSR ship. UR S5, S7 and S11 do not apply to CSR bulk carriers and oil tankers, which use 190/k at sea and net properties.
  • The k factor applied to inertia. The UR S11 minimum moment of inertia carries no k.
  • One 90% figure read as another. The table above separates them.
  • A loading instrument taken to compute the modulus. The section properties are approved inputs. IACS UR S1 requires the instrument to check moments and shear forces against permissible values.

Limitations

This article explains how the hull girder section modulus is calculated and checked. It is not a substitute for the approved midship section and the class society’s calculation for a real ship. Every requirement for a real ship is the one its classification society applies.

The example section is a simplified double hull with the longitudinals smeared into the plating. Its numbers show the mechanism only. A real section has discrete longitudinals, girders, brackets and corrosion margins, and its calculation follows the class society’s software.

The UR values here are from the revisions named in each section, and the CSR values from the 1 July 2025 consolidated edition. The value of φ in the UR S11.4.3 shear check is set by each classification society and is not given here. No hull-girder shear lag factor is given, because UR S5, UR S11 and CSR Pt 1 Ch 5 Sec 1 state none.

Frequently Asked Questions (FAQs)

Why does a ship have two section moduli?

A ship has one section modulus at the deck and one at the keel, because the neutral axis is not at mid-depth.

The moment of inertia is divided by the distance from the neutral axis to each point. IACS UR S5 measures the deck modulus to the molded deck line at side and the bottom modulus to the baseline. IACS UR S11.3.1.1 and UR S7 apply their requirements at both deck and keel.

Which members count in the midship section modulus?

Every continuous longitudinal strength member within 0.4L amidships counts under IACS UR S5 Corr.1.

That includes the deck and bottom plating, the side shell, the inner bottom, longitudinal bulkheads, and the longitudinals and girders attached to them. CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.1] counts all continuous longitudinal members below and including the strength deck.

Which openings are deducted from the section modulus?

Large openings are always deducted. IACS UR S5 defines them as openings exceeding 2.5 m in length or 1.2 m in breadth.

It also deducts scallops where scallop welding is used. CSR BC&OT adds circular openings exceeding 0.9 m in diameter. Smaller openings can stay in the calculation within the limits of the 3% test or the 0.06 rule.

What is the 3% rule for small openings?

Under IACS UR S5, small openings need not be deducted if they reduce the deck or bottom modulus by no more than 3%.

Their breadths in one section are summed for the test. Small openings include manholes, lightening holes and single scallops. The height of holes and scallops in longitudinals and girders must also not exceed 25% of the web depth, and 75 mm for scallops.

What is the 0.06 (B − Σb) rule?

IACS UR S5 accepts a sum of small opening breadths of 0.06 (B − Σb) in one section as equivalent to the 3% test.

B is the breadth of the ship and Σb the total breadth of large openings. CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.11] uses the same breadth limit and deducts only the excess.

Are lightening holes and scallops deducted?

Not if they are small enough.

IACS UR S5 leaves them in where their height is no more than 25% of the web depth of the longitudinal or girder. Scallops are limited to 75 mm, and the 3% test still applies. CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.12] uses 0.25 hw and deducts or compensates the excess.

How do continuous hatch coamings and trunks change the deck modulus?

IACS UR S5 includes continuous trunks and longitudinal hatch coamings when longitudinal bulkheads or deep girders support them effectively.

The deck modulus then uses yt = y (0.9 + 0.2 x/B) in place of the distance to the deck line, where that is greater. CSR BC&OT uses the same form for its equivalent deck line.

Do deckhouses and superstructures count in the section modulus?

Not in general. CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.3] excludes superstructures that do not form a strength deck, and deckhouses.

Where a superstructure or deckhouse contributes to longitudinal strength, CSR [1.3.1] takes its deck as the strength deck.

Do bilge keels and bulwarks count?

No. CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.3] lists the members that do not contribute.

They include bulwarks, gutter plates, bilge keels, and sniped or non-continuous stiffeners. None of them is continuous structure that carries the hull girder load.

Do vertically corrugated longitudinal bulkheads count?

They count for shear but not for bending.

CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.7] states that vertically corrugated longitudinal bulkheads are not effective for hull girder bending. They are effective for hull girder shear force.

How is the neutral axis of the hull girder found?

The neutral axis is at the height of the centroid of the counted section area.

CSR BC&OT Pt 1 Ch 5 App 1 [1.4.2] writes it as zn = Sy/A. Sy is the first moment of area about the baseline and A the total area. The moment of inertia about it is the moment about the baseline less zn² A, in [1.4.3].

What is the required section modulus under IACS UR S11?

IACS UR S11 Rev.10, S11.3.1.1, requires a section modulus of at least |Ms + Mw| / σ × 10³ cm³ within 0.4L amidships.

Ms and Mw are the still-water and wave bending moments in kNm, and σ is 175/k N/mm². The modulus is calculated by UR S5, and the block coefficient Cb is the UR S2 value.

What is the UR S7 minimum section modulus?

IACS UR S7 Rev.4 sets Wmin = c L² B (Cb + 0.7) k cm³ at deck and keel.

It applies to ships of 90 m to 500 m. The coefficient c is cn for new ships and cs = 0.9 cn for ships in service. Cb is not taken as less than 0.60.

Which governs, UR S11 or UR S7?

The larger requirement governs. IACS UR S11.3.1.1(ii) states that the longitudinal strength must in any case comply with UR S7.

UR S11 depends on the still-water moment, while UR S7 does not, so a lightly loaded ship can be governed by UR S7.

What is the minimum moment of inertia?

IACS UR S11 Rev.10, S11.3.1.2, requires a moment of inertia at the midship point of at least 3 C L³ B (Cb + 0.7) cm⁴.

The formula carries no material factor, so higher tensile steel does not reduce it. CSR BC&OT Pt 1 Ch 5 Sec 1 [2.3.1] sets 2.7 Cw L³ B (CB + 0.7) × 10⁻⁸ m⁴ on net properties.

Over what length must the section modulus be kept?

Within 0.4L amidships. IACS UR S7.2 and CSR BC&OT Pt 1 Ch 5 Sec 1 [2.1.1] require the continuous longitudinal scantlings to be kept over that length.

UR S7.2 allows a gradual reduction toward the ends of the 0.4L part in special cases.

What happens outside 0.4L amidships?

IACS UR S11.3.2 leaves the bending strength outside 0.4L to each classification society.

It requires checks at the forward end of the engine room and the forward end of the foremost hold. Ships with large deck openings are also checked near the quarter lengths. CSR applies the stress check along the full length.

How does higher tensile steel change the requirement?

Higher tensile steel raises the permissible stress 175/k, so the required section modulus falls by the factor k.

IACS UR S4 Rev.4 gives k of 0.78 for 315 N/mm² steel and 0.72 for 355 N/mm². For 390 N/mm² steel it is 0.68, or 0.66 with a fatigue assessment. The UR S7 minimum also carries k.

How far must higher tensile steel extend?

IACS UR S11 has no clause on the extent.

CSR BC&OT Pt 1 Ch 5 Sec 1 [2.4.1] sets the vertical extent by zhts ≥ z1 (1 − σperm/σL). Paragraph [2.4.2] keeps it continuous along the length until the stress is within the mild steel range.

What minimum section modulus does the CSR require?

CSR BC&OT Pt 1 Ch 5 Sec 1 [2.3.2] sets the minimum net modulus at deck and bottom.

It is 0.9 k Cw L² B (CB + 0.7) × 10⁻⁶ m³. The CSR calculates it on net properties, at the gross offered thickness less 0.5 tc.

Are hull girder properties calculated at gross or net thickness?

For a non-CSR ship, IACS UR S5 states no thickness basis and no corrosion deduction.

For a CSR ship, CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.2] uses the gross offered thickness less 0.5 tc for the yielding check. The buckling check uses gross less the full tc.

How is the side shell thickness for shear found?

IACS UR S11.4.2 sets the side shell thickness as t = 0.5 |Fs + Fw| S/(τ I) × 10² mm.

It applies to ships without effective longitudinal bulkheads. τ is 110/k N/mm². S is the first moment in cm³, and I the moment of inertia in cm⁴. A direct stress calculation approved by the society can show a smaller value.

How are longitudinal bulkheads treated in the shear check?

IACS UR S11.4.3 covers ships with two effective longitudinal bulkheads.

It gives each side shell (0.5 − φ) of the shear force and each bulkhead φ, plus a local load term. Each classification society gives the value of φ and the local load term. UR S11 states no number for φ.

What is S in the shear formula?

S is the first moment, in cm³, about the neutral axis of the area of the effective longitudinal members.

It is taken between the level where the shear stress is being found and the vertical extremity of those members (IACS UR S11.4.2). S is largest at the neutral axis, so the shear stress is largest there.

What is shear flow and how does the CSR compute it?

Shear flow is the shear force per unit length along the plating of the section.

CSR BC&OT Pt 1 Ch 5 App 1 applies a unit shear force of 1 N. It splits the flow into a determinate part and an indeterminate part. Closed cells are cut by virtual slits, and the indeterminate flow is constant around each cell.

What is effective breadth, and does the CSR give a rule?

Effective breadth is the width of plating that works with a stiffener or girder as its flange.

CSR BC&OT Pt 1 Ch 3 Sec 7 [1.3] gives rules for the attached plating of local stiffeners and primary supporting members. UR S5, UR S11 and CSR Pt 1 Ch 5 Sec 1 give no shear lag reduction factor for the hull girder modulus.

When must an oil tanker's section modulus be evaluated in service?

IACS UR Z10.1 Rev.25 applies to oil tankers of 130 m in length and upwards, as defined in the International Convention on Load Lines.

Their longitudinal strength is evaluated at the special survey after the ship is 10 years old. UR Z10.4 Rev.18 has the same rule for double hull oil tankers. The evaluation uses the measured, renewed and reinforced thicknesses.

What is the 10% flange area rule?

UR Z10.1 Annex III, 2.1.2, applies where the deck or bottom flange area has diminished by more than 10% of its as-built area.

The flanges are then renewed or reinforced to at least 90% of the as-built area, or the actual section modulus is calculated. The flange is the plating with its longitudinals.

What do the different 90% figures mean?

Three rules use 90% for different things.

UR S7 sets cs = 0.9 cn for ships in service. UR Z10.1 Annex III compares the actual modulus with 90% of the new-building S7 or S11 requirement. That test applies to oil tankers built on or after 1 July 2002. CSR Pt 1 Ch 13 Sec 2 [2.2.2] compares with the modulus at the gross offered thickness.

What is required for CSR ships in service?

CSR BC&OT Pt 1 Ch 13 Sec 2 [2.2] applies to ships over 10 years of age.

The current section modulus at deck and bottom must be at least 90% of the value at the gross offered thickness. Alternatively, the deck and bottom zone areas must be at least 90%. The check is not needed where every reduction is below 10% in the deck and bottom zones. In the neutral axis zone the limit is 0.5 tc.

Can a corrosion protection system reduce the minimum section modulus?

Only a little. IACS UR S7.3 allows certain reductions in tank boundary scantlings where an effective corrosion protection system is fitted.

UR S7.3 states that those reductions should in no case reduce the minimum hull girder section modulus of a new ship by more than 5%.

What does new ship mean in IACS UR S7?

The note to IACS UR S7 Rev.4 defines new ships as ships in the stage directly after completion.

They use the coefficient cn. Ships in service use cs = 0.9 cn. UR S7 itself states no age at which the in-service value applies.

Do aluminum or other non-steel members count?

They count at their steel-equivalent area.

CSR BC&OT Pt 1 Ch 5 Sec 1 [1.2.8] converts a non-steel member by the ratio of its Young’s modulus to 2.06 × 10⁵ N/mm². The converted area then enters the section properties.

Sources

  1. IACS UR S5 Corr.1 (June 2019). Calculation of Midship Section Moduli for Conventional Ship for Ship's Scantlings iacs.s3.af-south-1.amazonaws.com
  2. IACS UR S7 Rev.4 (May 2010). Minimum Longitudinal Strength Standards iacs.s3.af-south-1.amazonaws.com
  3. IACS UR S11 Rev.10 (Dec 2020). Longitudinal Strength Standard iacs.s3.af-south-1.amazonaws.com
  4. IACS CSR BC&OT (1 July 2025). Common Structural Rules for Bulk Carriers and Oil Tankers iacs.s3.af-south-1.amazonaws.com
  5. IACS UR Z10.1 Rev.25 (Feb 2023). Hull Surveys of Oil Tankers iacs.s3.af-south-1.amazonaws.com
  6. IACS UR Z10.4 Rev.18 (Feb 2023). Hull Surveys of Double Hull Oil Tankers iacs.s3.af-south-1.amazonaws.com
  7. IACS UR Z10.2 Rev.37 (Feb 2023). Hull Surveys of Bulk Carriers iacs.s3.af-south-1.amazonaws.com