Jacket cooling water system on marine diesel engines
The high-temperature fresh water circuit that cools a marine diesel engine's cylinder liners, cylinder covers and exhaust valves, held at a fixed outlet temperature.
The jacket cooling water system is the high-temperature fresh water circuit that removes heat from the cylinder liners, the cylinder covers and the exhaust valve housings of a marine diesel engine. On slow-speed two-stroke engines it is controlled at the engine outlet at a fixed temperature, independent of load: 85 °C on Everllence (MAN B&W) ME-C engines, or 87 °C where a separate freshwater generator valve is fitted, and 90 °C on WinGD X92-B engines.
The circuit carries more than one duty. Its heat drives the freshwater generator and jacket water heat recovery, its expansion tank sets the static pressure at the hottest cooled surfaces, and its treatment decides whether the cylinder cover cooling jackets scale and crack.
The full article will cover the circuit layout from pump to cooler, the thermostatic control and setpoints by maker, preheating and minimum start temperature, deaeration and the expansion tank, alarm and slowdown values, load-dependent liner cooling, and the interface with the central cooling system. See cylinder cover design and cooling and marine sea water cooling systems.