Marine Helicopter Operations and Helidecks
Helideck rules for ships and offshore units: SOLAS II-2/18, FSS Code Chapter 17, MODU Code Chapter 13 and CAP 437 on D-value, foam, markings, HMS and winching.
Contents18 sections
A helideck is a purpose-built helicopter landing area on a ship, together with the structure, fire-fighting appliances and other equipment needed to operate helicopters safely, as defined in SOLAS regulation II-2/3.26. Every ship equipped with one must meet SOLAS II-2/18, which entered into force on 1 July 2002 through resolution MSC.99(73). Since 1 January 2020 its foam protection on newly constructed ships has followed Chapter 17 of the FSS Code. Drilling units follow Chapter 13 of the 2009 MODU Code, and the aviation side follows ICAO Annex 14 Volume II. The UK Civil Aviation Authority’s CAP 437 is the most detailed national overlay, and its 2026 text is the source of most of the geometry, lighting, friction and motion figures in this article.
Helicopter operations at sea involve two regimes at once. The ship’s flag Administration certifies the deck as part of the ship, under IMO instruments. The helicopter operator and the coastal State’s aviation authority decide whether an aircraft may use it, against aviation standards. A deck that satisfies one regime can still be refused by the other, so the article treats each criterion under the instrument that sets it.
Regulatory framework: IMO, ICAO and the national overlays
Seven instruments carry almost every helideck requirement that applies in 2026. Four are mandatory IMO texts, one is a recommendatory IMO code, one is an ICAO annex, and one is a UK national standard; each reaches a different party on a different date.
| Instrument | Body and identifier | Binds | Date |
|---|---|---|---|
| SOLAS II-2/18 Helicopter facilities | IMO, MSC.99(73) | Ships equipped with helidecks | In force 1 July 2002 |
| SOLAS II-2/3.57, 3.58, 18.2.3, 18.5.1.6 | IMO, MSC.404(96) | Ships constructed on or after 1 January 2020 | In force 1 January 2020 |
| FSS Code Chapter 17 | IMO, MSC.403(96) | Foam appliances on those ships | In force 1 January 2020 |
| 2009 MODU Code, Chapter 13 and 9.16 | IMO Assembly, A.1023(26) | Drilling units, through flag law | Adopted 2 December 2009 |
| SOLAS III/28 | IMO, MSC.47(66) | Ro-ro passenger ships and the passenger ships in III/28.2 | In force 1 July 1998 |
| Annex 14 Volume II, Heliports | ICAO, Fifth Edition | Contracting States’ heliport rules | July 2020; Amendment 10 applicable 27 November 2025 |
| CAP 437 | UK CAA, Edition 9, Amendment 01/2026 | Helidecks used by UK offshore operators | February 2023; January 2026 |
SOLAS Chapter II-2 Regulation 18
Regulation 18 sits in Part G of SOLAS Chapter II-2, the revised chapter adopted by the Maritime Safety Committee in MSC.99(73) on 5 December 2000. Paragraph 18.1 states four functional requirements: helideck structure, fire-fighting appliances, refueling and hangar facilities, and operation manuals and training. The paragraphs that follow implement them in order: 18.3 structure, 18.4 means of escape, 18.5 fire-fighting appliances, 18.6 drainage, 18.7 refueling and hangars, and 18.8 the operations manual and personnel.
The regulation applies to “ships equipped with helidecks” (18.2.1). It contains no passenger-number threshold and no tonnage threshold, and it sets no structural load factor. A ship without a helideck that takes a helicopter occasionally or in an emergency may use its ordinary Part C fire-fighting equipment, kept close to the landing or winching area during the operation (18.2.2).
FSS Code Chapter 17 and the 2020 amendments
MSC.404(96) and MSC.403(96), both adopted on 19 May 2016 and both in force on 1 January 2020, split the foam rules by construction date. MSC.404(96) added two definitions to SOLAS II-2/3 (3.57 helicopter landing area, 3.58 winching area), a new 18.2.3 for landing areas, and a new 18.5.1.6 that replaces the old foam, agent and nozzle paragraphs with FSS Code Chapter 17 on ships constructed on or after that date. MSC.403(96) wrote Chapter 17, “Helicopter facility foam firefighting appliances”, into the FSS Code. Neither resolution is retroactive.
The 2009 MODU Code
The 2009 MODU Code, adopted by Assembly resolution A.1023(26) on 2 December 2009, superseded the 1989 Code (A.649(16)). Its preamble names ICAO amendments affecting helicopter facilities as one reason for the revision. Helicopter facilities are Chapter 13, their fire-fighting is section 9.16, communications section 11.6, and operating procedures section 14.2. The Code is written in “should” throughout and reaches a mobile offshore drilling unit only through the law of its flag State.
ICAO Annex 14 Volume II
Annex 14 Volume II, Heliports, is the ICAO standard that national aviation authorities implement. The Fifth Edition of July 2020 superseded all earlier editions on 5 November 2020. Amendment 10, adopted 28 March 2025, became applicable on 27 November 2025, except its section 1.4 on heliport certification, applicable from 26 November 2026. Section 3.3 covers shipboard heliports and distinguishes purpose-built decks, at the bow, the stern or above the ship’s structure, from non-purpose-built areas elsewhere on the ship. Chapter 6 covers heliport emergency response.
CAP 437 and the other national overlays
CAP 437, Standards for Offshore Helicopter Landing Areas, is published by the UK Civil Aviation Authority. It was first published in 1981; the current text is Edition 9 of February 2023 with Amendment 01/2026 of January 2026, which adds Appendix L, a Master Minimum Helideck Equipment List for the UK. The Helideck Certification Agency (HCA) audits and inspects helidecks on offshore installations and vessels in UK waters against CAP 437, on behalf of the UK offshore helicopter operators, and publishes the Helideck Limitations List (HLL) that pilots fly to.
CAP 437 is a regional overlay, not an IMO instrument. Where a ship or unit works outside UK waters, the coastal State’s aviation authority sets the national standard, and the helicopter operator’s own acceptance process decides whether a deck is used. Ships trading worldwide therefore start from SOLAS and the FSS Code, and add CAP 437 where their work brings them to UK operators.
Helideck, helicopter landing area and winching area
SOLAS recognizes three kinds of shipboard helicopter area, and the obligations fall away sharply from the first to the third. The definitions below are the treaty text.
| Helideck | Helicopter landing area | Winching area | |
|---|---|---|---|
| SOLAS definition | II-2/3.26 | II-2/3.57 (MSC.404(96)) | II-2/3.58 (MSC.404(96)) |
| Meaning | Purpose-built landing area with its structure and fire-fighting appliances | Designated for occasional or emergency landing, not designed for routine operations | Pick-up area for transfer of personnel or stores while the helicopter hovers |
| Helicopter lands | Yes, routinely | Yes, occasionally | No |
| Fire-fighting, ship built before 1 January 2020 | Full II-2/18.5.1 list and Table 18.1 foam | Part C equipment nearby (18.2.2) | Part C equipment nearby (18.2.2) |
| Fire-fighting, ship built on or after 1 January 2020 | FSS Code Chapter 17 helideck provisions | FSS Code Chapter 17 landing-area provisions (18.2.3) | Part C equipment nearby (18.2.2) |
| Aviation geometry | ICAO Annex 14 Vol II 3.3; CAP 437 Chapters 3 and 4 | ICAO non-purpose-built heliport; CAP 437 Chapter 9 | CAP 437 Chapter 10; ICS Guide |
The FSS Code landing-area provision (Chapter 17 paragraph 3.4) asks for less than a helideck: two portable foam applicators or two hose-reel foam stations, each at the Table 18.1 rate for the helicopter’s length band, with concentrate for at least 10 minutes. On a tanker, the Administration may accept the deck foam system instead.
CAP 437 Chapter 9 covers landing areas on the ship’s side that were not purpose-built. Its paragraph 9.18 calls for a 1D clear zone, a yellow touchdown/positioning circle with an inner diameter of 0.5D and a line at least 0.5 m wide, an enclosed area preferably dark green, and a white H of 4 m by 3 m with its cross bar parallel to the ship’s side.
D-value, t-value and landing-area geometry
Every dimension of a helideck is a multiple of one number, the D-value of the largest helicopter the deck is certified for. The second painted number, the t-value, limits the helicopter’s mass.
The D-value
FSS Code Chapter 17 paragraph 2.1 defines the D-value as the largest dimension of the helicopter when its rotors are turning, and states that it sets the area over which foam must be applied. CAP 437 adds the method: from the most forward position of the main rotor tip path plane to the most rearward position of the tail rotor tip path plane, or the rearmost point of the fuselage on a Fenestron or Notar tail. The deck’s “D-circle” has a diameter equal to the D-value of the largest helicopter it is intended to serve.
CAP 437 paragraph 5.13 works its foam example on the Sikorsky S-92 at D = 20.88 m. A footnote to the 2009 MODU Code paragraph 13.5.7 gives the AS332L2 and the EC 225 a D-value of 19.5 m each, rounded up to 20 on the deck marking. For any other type, take the D-value from the helicopter operator or the type documentation for the specific variant, because rotor and tail changes alter it.
The t-value
The t-value is the maximum allowable mass in tonnes. The 2009 MODU Code paragraph 13.5.9 specifies the marking: a two- or three-digit number followed by the letter “t”, to one decimal place, rounded to the nearest 100 kg. CAP 437 uses the same symbol in the same sense. It is a structural mass limit and has nothing to do with touchdown accuracy or ship motion.
Size of the landing area: 1D and 0.83D
The landing area must contain a circle of not less than 1D for single main rotor helicopters (2009 MODU Code 13.3.2.1; ICAO Annex 14 Volume II 3.3.4 and 3.3.7). On a helideck the final approach and take-off area (FATO) and the touchdown and lift-off area (TLOF) are presumed to coincide (MODU Code 13.2.5), and the TLOF must be dynamic load-bearing.
Two exceptions allow less than 1D:
- Benign climates. The MODU Code 13.3.3.1 accepts a circle of not less than 0.83D where the coastal State determines the climate to be benign.
- Bow and stern heliports with limited headings. ICAO Annex 14 Volume II 3.3.8 accepts two opposing 1D arcs with a minimum width of 0.83D, with the touchdown heading limited by 15 degrees at each end of the arc.
CAP 437 Appendix H sets out the risk assessment for a helideck smaller than 1D.
Obstacle-free and limited obstacle sectors
The obstacle-free sector (OFS) is an arc of at least 210 degrees whose apex lies on the D-circle (MODU Code 13.3.2.2; FSS Code Chapter 17 paragraph 2.8). Nothing may stand above the landing surface in it except essential items: CAP 437 paragraph 3.23 caps those at 15 cm, or 5 cm where the D-value is 16.00 m or less, and FSS Chapter 17 paragraph 3.11 caps fire-fighting equipment in the sector at 0.25 m. Below deck level, a 5:1 falling gradient must stay clear over an arc of at least 180 degrees.
The remaining 150 degrees is the limited obstacle sector (LOS). Out to 0.12D from the landing circle, objects should not exceed 0.25 m; over a further 0.21D they must stay below a 1:2 gradient starting at a height of 0.05D (MODU Code 13.3.2.3). CAP 437 paragraph 3.25 allows the OFS bisector to be swung by up to 15 degrees, normally only on existing installations. A black chevron marks the origin of the OFS (MODU Code 13.5.15).
Where an offshore crane, flare structure, exhaust stack or derrick intrudes into these sectors and cannot be moved, any resulting limits are set by the helicopter operators and promulgated in the HLL (CAP 437 paragraph 6.3).
Air gap, turbulence and hot exhaust
CAP 437 paragraph 3.9 sets a general limit of 1.75 m/s on the standard deviation of the vertical airflow velocity over the deck, to be checked by wind-tunnel testing or computational fluid dynamics on every new helideck and on every topside change that could alter the airflow. It treats 1.75 m/s as an advisory threshold and 2.4 m/s as the level above which deck modifications, such as a larger air gap, are worth considering. The older 0.9 m/s vertical wind criterion was withdrawn after CAA Paper 2008/02.
Paragraph 3.10 sets the thermal criterion: where modelling shows an air temperature rise of more than 2 degrees C, averaged over three seconds, the helicopter operator must be consulted so that restrictions can be applied. ICAO Annex 14 Volume II 3.3.10 notes the Heliport Manual’s guidance that a sufficient air gap under a deck is at least 3 m, except over shallow superstructures.
Fire-fighting appliances: SOLAS Table 18.1, FSS Chapter 17, MODU Code and CAP 437
Helideck foam is one of the fixed fire-fighting systems that SOLAS Chapter II-2 regulates, and the required quantity depends on whether the ship was constructed before 1 January 2020, whether the unit is a MODU, and whether CAP 437 applies. The four regimes differ in both rate and basis.
| Regime | Foam basis | Rate | Duration |
|---|---|---|---|
| SOLAS II-2/18.5.1.3, Table 18.1 (ships built before 1 January 2020) | Helicopter overall length | 250 l/min below 15 m; 500 l/min 15 m to below 24 m; 800 l/min 24 m to below 35 m | At least 5 min |
| FSS Code Chapter 17 helideck (ships built on or after 1 January 2020) | D-value area, or whole helideck area for deck-integrated nozzles | 6 l/min per m2 | At least 5 min |
| 2009 MODU Code 9.16.4.3 | Circle of diameter D | 6 l/m2 per minute | At least 5 min, starting within 30 s |
| CAP 437 paragraph 5.12 | D-circle, by ICAO foam performance level | 5.5 l/m2 per minute (Level B); 3.75 (Level C) | 5 min generally reasonable (5.14) |
The CAP 437 Level B rate of 5.5 is below the FSS Chapter 17 rate of 6. A ship built in or after 2020 that meets Chapter 17 therefore also meets the CAP 437 Level B rate, while a deck designed only to CAP 437 can fall short of Chapter 17. CAP 437 paragraph 5.13 works the S-92 case: 5.5 x pi x 10.44 squared gives 1,883 l/min at Level B, and 1,284 l/min at Level C. At the FSS Chapter 17 rate the same D-circle needs about 2,054 l/min.
Ships constructed before 1 January 2020
SOLAS II-2/18.5.1 as adopted by MSC.99(73) requires, close to the helideck and near its means of access:
- at least two dry powder extinguishers with a total capacity of not less than 45 kg;
- carbon dioxide extinguishers with a total capacity of not less than 18 kg, or equivalent;
- a foam application system of monitors or foam-making branch pipes able to reach all parts of the helideck in all weather in which helicopters can operate, at the Table 18.1 rate for at least 5 minutes;
- a principal agent suitable for use with salt water;
- at least two dual-purpose (jet and spray) nozzles with hoses that reach any part of the helideck;
- two sets of fire-fighter’s outfits in addition to those required by Regulation 10.10;
- a ten-item equipment list: adjustable wrench, fire-resistant blanket, 60 cm bolt cutters, grab or salving hook, heavy-duty hacksaw with six spare blades, ladder, 5 mm lift line 15 m long, side-cutting pliers, assorted screwdrivers, and a harness knife with sheath.
Ships constructed on or after 1 January 2020
On these ships SOLAS II-2/18.5.1.6 replaces items 3 to 5 with FSS Code Chapter 17. The dry powder, CO2, outfits and equipment list remain. For a helideck, Chapter 17 paragraph 3.2 requires:
- at least two fixed foam monitors, or a deck-integrated foam nozzle system, plus at least two hose reels with a foam-making branch pipe and non-collapsible hose;
- a minimum system rate of the D-value area times 6 l/min per m2, or the whole helideck area times 6 for a deck-integrated nozzle system;
- each monitor delivering at least 50% of that minimum and not less than 500 l/min, and each hose reel at least 400 l/min;
- concentrate for at least 5 minutes of discharge.
Further paragraphs fix the hardware. The monitor’s distance to the farthest part of the deck may not exceed 75% of its still-air throw (3.3), and every nozzle must throw at least 15 m with all discharging together (3.8). There must be release stations at each monitor and hose reel plus a central manual release, with foam at nominal flow and pressure within 30 seconds of activation (3.5). Automatic release is optional (3.1).
Materials are brass, bronze or stainless steel, with piping that withstands 925 degrees C (3.9). Monitors of up to 1,000 l/min need an air-aspirating nozzle; non-aspirating nozzles are allowed only above 1,000 l/min (3.14). Oscillating monitors must be pre-set to spray and able to be disengaged (3.13), and access to the release stations must not require crossing the helideck (3.12).
MODU Code section 9.16
The 2009 MODU Code paragraph 9.16.4 asks for at least two dry powder extinguishers totalling not less than 45 kg, with none under 9 kg, and CO2 totalling not less than 18 kg. Foam is 6 l/m2 per minute within a circle of diameter D for at least 5 minutes, starting within 30 seconds of activation, with a footnote pointing to ICAO performance Level B foam. Its equipment list adds a crowbar to the SOLAS list and doubles the lift line to 30 m.
Deck integrated fire-fighting systems
A deck integrated fire-fighting system (DIFFS, in CAP 437’s expansion) uses nozzles recessed into, or mounted on the edge of, the deck surface (FSS Chapter 17 paragraph 2.2) in place of monitors. It removes the monitor and its operator from the deck edge. Under FSS Chapter 17, a DIFFS is rated on the whole helideck area, not just the D-value area, so it needs at least as much flow as a monitor system on the same deck, and more wherever the deck is larger than the D-circle.
CAP 437 adds two rules. Paragraph 5.16 requires additional aspirated hose lines where a non-aspirated system protects a solid plate deck, and paragraph 5.17 requires at least two hand-controlled foam branches of 225 to 250 l/min each. Paragraph 5.14 accepts no less than 3 minutes of water-only discharge where the deck has a passive fire-retarding surface. Paragraph 5.2 points ships with non-purpose-built heliports back to SOLAS Part C if constructed before 1 January 2020 and to FSS Chapter 17 if constructed on or after that date.
Structure, drainage, escape and structural loads
SOLAS II-2/18.3 requires a helideck of steel or equivalent material. Where the helideck forms the deckhead of a deckhouse or superstructure it must be insulated to A-60 class. Where the Administration permits aluminum or another low-melting-point metal, the conditions depend on where the deck sits (18.3.2): a platform cantilevered over the side needs a structural analysis after each fire on the ship or the platform, and a platform above a deckhouse needs no openings in the deckhouse top and bulkheads below it and steel shutters on the windows beneath.
Regulation 18.4 requires a main and an emergency means of escape and access for fire-fighting and rescue personnel, preferably on opposite sides of the helideck. Regulation 18.6 requires drainage of steel leading directly overboard, independent of any other system, and not discharging onto any part of the ship. Burning fuel running into the ship is the hazard both paragraphs address.
SOLAS sets no design load. The figures that classification societies and designers use come from CAP 437 paragraph 3.20, with detailed design referred to ISO 19901-3:2014 for topsides structure:
| Load case (CAP 437) | Value |
|---|---|
| Heavy normal landing | 1.5 x MTOM of the design helicopter |
| Emergency landing, any position | 2.5 x MTOM; “will usually govern the design” |
| Structural response factor | 1.3, unless a lower factor is justified |
| Superimposed load on whole deck | 0.5 kN per m2 |
| Lateral load | 0.5 x MTOM |
| Restricting wind for operations | 60 kt (31 m/s) |
| Floating installations, storm case | 10-year return period |
| Helicopter at rest (3.21) | 1 x MTOM |
| Punching shear wheel contact area | 65 x 10^3 mm2 |
MTOM is the maximum certificated take-off mass. CAP 437 paragraphs 3.47 and 3.48 call for flush tie-down points sized for the largest helicopter, with a maximum tie-down bar diameter of 22 mm, and its Figure 4 does not require the outer tie-down circle where the D-value is less than 22.2 m. The MODU Code 13.4.2 calls for a perimeter safety net inclined upwards at 10 degrees to a horizontal distance of 1.5 m.
Markings and lighting
Day markings and night lighting are aviation cues, and the specifications come from ICAO Annex 14 Volume II, the MODU Code Chapter 13 and CAP 437 Chapter 4 and Appendix C. They agree on the core figures.
Day markings
| Marking | Specification | Source |
|---|---|---|
| Landing area perimeter | Continuous white line at least 0.3 m wide | MODU Code 13.5.11 |
| Touchdown/positioning (TD/PM) circle | Yellow, line width 1 m, inner diameter 0.5D | MODU Code 13.5.14; CAP 437 4.13 |
| H | White, 4 m high, 3 m wide, stroke 0.75 m; cross bar on the OFS bisector | MODU Code 13.5.5; CAP 437 4.14 |
| D-value | Whole metres, 0.5 rounded down | MODU Code 13.5.7 |
| Maximum allowable mass | Number in tonnes to one decimal place, followed by “t” | MODU Code 13.5.9; CAP 437 4.12 |
| OFS origin | Black chevron, legs 0.8 m by 0.1 m | MODU Code 13.5.15 |
| Wind direction indicator | Cone 1.2 m long, 0.3 m and 0.15 m diameters, visible from at least 200 m | MODU Code 13.5.3 |
CAP 437 allows two reductions on new-build helidecks with a D-value below 16 m: a TD/PM line width of 0.5 m and an H of 3.0 m by 2.0 m with a 0.5 m stroke. It also allows the TD/PM circle to be offset by up to 0.1D from the OFS origin where an aeronautical study supports it.
Night lighting
Green perimeter lights stand at intervals of not more than 3 m, with at least four per side on a square or rectangular deck. They are limited to 15 cm high where D exceeds 16.00 m and 5 cm where it is 16.00 m or less (CAP 437 Appendix C.16). Their intensity is set by elevation:
| Elevation | Minimum intensity |
|---|---|
| 0 to 10 degrees | 30 cd |
| Over 10 to 20 degrees | 15 cd |
| Over 20 to 90 degrees | 3 cd |
| Any angle | 60 cd maximum |
CAP 437 considers the perimeter ring serviceable when at least 90% of the lights work and no two adjacent lights are out (C.20). The lit TD/PM circle has at least 16 segments, each at least 40 mm wide, covering 50% to 75% of the circumference. The lit H is 3.9 to 4.1 m high and 2.9 to 3.1 m wide, with a stroke of 0.7 to 0.8 m.
In the UK continental shelf, the lit TD/PM circle and lit H have been mandatory for night operations since 1 April 2018, now under CAA Safety Directive SD-2022/001 of 1 June 2022. CAP 437 paragraph 4.23 states that floodlighting is no longer accepted as the primary visual cue, and paragraph 4.22 asks for any installed floodlights to be switched off during helicopter movements.
Obstacles get red lights of at least 10 cd, with intermediate lights every 10 m on any object more than 15 m higher than the landing area, and a red light of 25 to 200 cd on the highest point (MODU Code 13.5.24 and 13.5.25). The helideck status light is a flashing red light, initiated automatically by a hazard such as a gas release and manually by the HLO. Under MODU Code 13.5.26 it gives at least 700 cd between 2 and 10 degrees above the horizontal at 120 flashes per minute, dimmable to 60 cd with an aircraft on deck.
Helideck motion and the helideck monitoring system
A floating deck moves, and the helicopter operator, not the ship, sets the limits it may move within. CAP 437 Chapter 6 states that the limits are set by the helicopter operators and promulgated in the HCA’s Helideck Limitations List, as limits on pitch, roll, inclination, Significant Heave Rate (SHR) and the Motion Severity Index (MSI) and Wind Severity Index (WSI).
A helideck monitoring system (HMS) measures those parameters at the deck. CAP 437 defines each one:
- Pitch, roll and inclination: the maxima over the previous 20 minutes, relative to true vertical, to one decimal place (6.5).
- SHR: twice the root mean square heave rate over the previous 20 minutes, in m/s to one decimal place (6.6).
- MSI and WSI: indices combining deck motion and wind; CAP 437 paragraph 6.7 states that no individual limits per helicopter type are available, and a single generic limit is held in the HMS standard and HLL Part C.
The HMS repeater lights show the result to the pilot. Steady blue means safe to land. Steady amber means land with caution, because only MSI or WSI is out of limits. Steady red means do not land, because pitch, roll, inclination or SHR is out of limits (6.4). The HMS standard is published by the HCA. On the UK continental shelf, an HMS meeting Revision 9 or later has been mandatory since 1 April 2021, now under SD-2022/001, and should meet Revision 9c from 1 October 2025 (6.11).
With no HMS, or with it inoperative, the deck is held to the HLL Part C stable-deck conditions: maximum pitch and roll of 1 degree and maximum SHR of 0.4 m/s. That is a narrow window on any ship motions envelope, and CAP 437 paragraph 6.10 strongly recommends an HMS on every moving helideck. The 2009 MODU Code 13.6 makes the same point for surface units, asking for an electronic system that measures pitch, roll and heave and their rates at the helideck, displayed at the aeronautical VHF station.
Ship handling is the master’s lever on these numbers. Heading the ship to put the wind within the OFS and the sea where seakeeping is kindest, reducing speed, and using roll stabilizers all change the HMS readings. A dynamic positioning vessel can hold the heading the pilot asks for. The pre-flight weather report from a vessel adds maximum pitch, maximum roll, maximum inclination, SHR and helideck status to the meteorological data (CAP 437 6.16 to 6.19), and CAP 437 6.14 gives a reported example of pitch 2.1 up and 2.3 down, roll 1.6 left and 3.6 right, SHR 1.1 m/s and maximum inclination 2.8 degrees.
The helicopter landing officer and the fire-fighting team
SOLAS II-2/18.8.3 requires fire-fighting personnel of at least two persons trained for rescue and fire-fighting duties, with their equipment, to be immediately available at all times when helicopter operations are expected. The MODU Code 14.2.3 specifies when: when the helicopter is about to land, landing, refueling, or taking off. SOLAS 18.8.5 requires on-board refresher training, with additional extinguishing media for training and testing.
CAP 437 takes a different route. Paragraph 5.48 sizes the team by task resource analysis, covering the worst-case post-crash fire with rescue of occupants, rather than by a fixed head-count. Paragraph 5.49 requires the helicopter landing officer (HLO) to be identifiable to the helicopter crew as the person in charge of helideck operations, preferably by a brightly colored fire-retardant tabard marked “HLO”. Paragraphs 5.50 to 5.52 set the personal protective equipment, to standards that include EN 443 helmets, EN 659 gloves and EN ISO 20345 boots.
Training is set by reference, not by syllabus. CAP 437 paragraph 5.54 recommends that personnel attend an established helicopter fire-fighting course, and Appendix K paragraph K.41 states that all helideck teams should be trained to the Offshore Petroleum Industry Training Organisation (OPITO) standard or equivalent. On a merchant ship the helideck team are crew, so this training sits alongside the STCW basic safety training in STCW Chapter VI and the ship’s drills under its ISM Code safety management system.
The operations manual ties the roles together. SOLAS II-2/18.8.1 requires every helicopter facility to have one, describing the facility with a checklist of safety precautions, procedures and equipment, and allows it to form part of the ship’s emergency response procedures. The MODU Code 14.2.1 asks for the same in the unit’s operating manual.
Refueling and hangars
SOLAS II-2/18.7 governs any ship that refuels helicopters or houses them, in thirteen sub-paragraphs:
- a designated fuel tank storage area, remote from accommodation, escape routes and embarkation stations, and isolated from vapor ignition sources;
- spill collection and drainage, and protection of the tanks;
- portable tank design, securing, electrical bonding and inspection;
- a pump shutdown from a safe remote location, and only one tank connected to the pumping unit at a time, through steel piping as short as practicable;
- electrical equipment suited to the hazard, protection of the delivery and filling hoses against over-pressure, bonding of all equipment, and “NO SMOKING” signs.
Hangar, refueling and maintenance facilities are treated as a machinery space of category A for structural fire protection, fixed fire-extinguishing and detection. Enclosed hangar or refueling spaces are mechanically ventilated, as for closed ro-ro spaces of cargo ships, with non-sparking fans. Regulation 18.8.2 requires refueling procedures in line with recognized safe practice, and 18.8.4 keeps the fire team present but out of the refueling itself.
CAP 437 Chapters 7 and 8 set out the offshore helicopter refueling installation in detail. Paragraph 7.5 recognizes two layouts, a transportable tank system and a static storage tank system. Paragraph 7.7 identifies the fuel as Jet A-1 with a flash point of at least 38 degrees C, and notes the static electricity hazard that fuel movement creates. The filtration references have changed: CAP 437 7.15.5 records that the Energy Institute withdrew EI 1583, and lists EI 1588 water barrier elements, EI 1598 electronic water sensors and EI 1599 dirt defence filters, with filter water separators to EI 1581.
Water detection is a quality control point. CAP 437 paragraph 8.14 states that water-finding paper or paste is no longer recommended because it does not meet the minimum standard of detecting 30 ppm of water at the fuel delivery point. Chemical water detector capsules are used sealed, before their expiry month, and not reused. Paragraph 8.15 specifies a manual sample in a 3-litre glass jar.
Winching areas
A helicopter winching area transfers people or stores while the helicopter hovers, so the ship needs a clear area, not a landing deck. CAP 437 paragraph 10.1 states that, where practicable, the helicopter should always land rather than hoist, which makes winching the fallback. Paragraph 10.2 notes that the International Chamber of Shipping’s Guide to Helicopter/Ship Operations was updated to a 6th edition in 2025, and the CAP 437 winching-area figures follow it.
| Element | CAP 437 Chapter 10 |
|---|---|
| Manoeuvring zone | Diameter at least 2D |
| Clear zone | At least 5 m diameter, solid surface, centered in the maneuvering zone, painted a conspicuous color, preferably yellow, non-slip |
| Inner maneuvering zone obstructions | Not higher than 3 m |
| Outer maneuvering zone obstructions | Not higher than 6 m |
| Outer zone boundary | Broken circle, line width at least 30 cm, mark-to-space about 4:1, preferably yellow |
| Inner zone boundary | Thin white line about 10 cm |
| Lettering | “WINCH ONLY” in characters at least 2 m high |
| Night | Shielded floodlighting of the clear and maneuvering zones |
Winching above accommodation is restricted by paragraph 10.13 to twin-engined helicopters. The spaces below must be cleared, two independent access routes kept open, doors and ports closed, and fire and rescue personnel kept ready but sheltered. SOLAS has no winching-area equipment list beyond II-2/18.2.2, so the Part C equipment sits ready near the area during the operation.
Offshore support vessels and wind turbine installation vessels are frequent users. CAP 437 Chapter 10 also covers winching areas on wind turbine platforms. A merchant ship meets winching mainly in search and rescue and medical evacuation, coordinated through the rescue coordination center under the SAR Convention and the procedures of the IAMSAR Manual.
Ro-ro passenger ships: SOLAS III/28
SOLAS III/28, Helicopter landing and pick-up areas, was adopted with the revised SOLAS Chapter III by MSC.47(66) on 4 June 1996 and entered into force on 1 July 1998. Paragraph 28.1 requires every ro-ro passenger ship to have a helicopter pick-up area approved by the Administration, having regard to IMO’s recommendations. Paragraph 28.2, as adopted, requires “Passenger ships of 130 m in length and upwards, constructed on or after 1 July 1999” to be fitted with a helicopter landing area approved on the same basis.
The two chapters are linked in both directions. SOLAS II-2/18.2.4, as renumbered by MSC.404(96), states that ro-ro passenger ships without helidecks shall comply with III/28. A ro-ro vessel with a full helideck therefore meets II-2/18; one without meets III/28 and keeps Part C equipment by the area under 18.2.2. III/28 was adopted in the same 1996 revision of Chapter III as the decision support system for masters of passenger ships in III/29.
Helicopter passengers: HUET, emergency breathing systems and survival suits
Passengers flying to an offshore installation or a vessel are trained and equipped for a ditching. The CAP 437 Appendix K inbound flight preparation checklist, for UK commercial air transport flights, confirms that every passenger holds the required certification, naming Category A emergency breathing system (CAT A EBS) and BOSIET or HUET training. It then checks that survival suits and CAT A EBS lifejackets are worn correctly, with personal items stowed, before boarding.
Helicopter underwater escape training (HUET) teaches escape from an inverted, flooded cabin, and BOSIET is the OPITO basic offshore safety induction and emergency training course that includes it. The inbound checklist also covers passenger and baggage weights against the manifest, prohibited items and portable electronic devices.
Ships that carry industrial personnel under SOLAS Chapter XV often move them by helicopter, as do FPSO units and drilling rigs. The helicopter operator, not the ship, sets the passenger equipment standard, and the ship’s role is to receive passengers whose training the operator has checked.
Emergency response on the helideck
A crash or fire on deck is a planned-for event, and three instruments shape the response. SOLAS II-2/18.8.1 allows the helicopter operations manual to form part of the ship’s emergency response procedures. CAP 437 paragraph 5.57 calls for a heliport emergency plan in line with ICAO Annex 14 Volume II Chapter 6, section 6.1. The 2009 MODU Code 13.5.26 links the flashing red status light to the unit’s gas detection, so a gas release closes the deck to an approaching aircraft automatically.
The equipment sets the first minutes. Foam must reach design flow within 30 seconds (FSS Chapter 17 paragraph 3.5), dry powder and CO2 back it up, and the SOLAS equipment list (bolt cutters, hacksaw, grab hook, harness knife) is rescue kit for cutting into an airframe. CAP 437 paragraph 5.48 builds the team around a worst-case post-crash fire with rescue of the occupants.
A ditching near the ship becomes a rescue under SOLAS Chapter III, using the ship’s rescue boat, a fast rescue boat where carried, and lifeboats and survival craft as the LSA Code specifies them. Alerting runs through GMDSS, and the helicopter’s own beacon or a ship’s EPIRB gives the satellite position, with an AIS-SART as the short-range homing aid. Offshore installations add their own emergency response arrangements and standby vessels.
Certification, inspection and surface friction
Certification runs on two tracks. The flag Administration, or a classification society acting for it, approves the helideck as SOLAS structure and fire-fighting equipment and records it in the ship’s safety certification, and port State control can examine the Regulation 18 equipment like any other fire-fighting appliance. The aviation side certifies the deck for helicopter use: in UK waters the HCA inspects against CAP 437 and lists the deck’s limitations in the HLL. Class societies publish optional helideck notations on top of the statutory approval.
Surface friction is the one helideck property CAP 437 requires to be measured on a fixed cycle. Its Table 3 sets minimum average values:
| Area | Fixed helideck | Moving helideck |
|---|---|---|
| Inside the TD/PM circle | 0.6 | 0.65 |
| TD/PM circle and H painted markings | 0.6 | 0.65 |
| Outside the TD/PM circle and parking areas | 0.5 | 0.5 |
Any installation that needs an HMS counts as a moving helideck unless it is fixed to the seabed. CAP 437 paragraph 3.41 requires a whole-deck survey in two orthogonal directions at a resolution of at least 1 m2, with a braked-wheel tester using helicopter-tyre material, on a wet surface, with electronic data. Appendix G gives an example protocol. The survey is repeated annually and after any remedial work. Where every required area exceeds its minimum by at least 0.1, the retest interval extends to two years, except where a landing net is used to mitigate friction.
The painted markings are held to the same 0.6 or 0.65 figure as the surface inside the circle, so a marking repainted with an unspecified coating can fail a deck that otherwise passes. The 2009 MODU Code 13.3.4 asks only for a skid-resistant surface, without a coefficient, so the number a MODU actually meets is set by the aviation authority and the helicopter operator.
Limitations
This article covers the international baseline (SOLAS, the FSS Code, the 2009 MODU Code and ICAO Annex 14 Volume II) and one national overlay, CAP 437 Edition 9 Amendment 01/2026. Other coastal States’ offshore helideck rules, including those of Norway, the United States and Australia, are not covered, and a deck working in their waters must meet them in addition.
SOLAS figures are given as adopted by MSC.99(73), MSC.404(96) and MSC.47(66). A flag Administration may require more than the minimum, and may have accepted equivalents on a given ship. Check the ship’s approved drawings and its operations manual before relying on a figure here.
CAP 437 figures change at each amendment, and its HMS limits sit in the HCA’s HMS standard and HLL rather than in CAP 437 itself. Helicopter D-values and masses are given only for the types named in CAP 437 and the MODU Code; for any other type, the helicopter operator’s figures govern. The ICS Guide to Helicopter/Ship Operations, 6th edition 2025, is cited only as CAP 437 reports it.
Nothing here is structural design guidance. A helideck is designed to the class society’s rules and to ISO 19901-3:2014 or the standard the class society names, by a qualified engineer, and approved by the flag Administration and the aviation authority concerned.
Frequently Asked Questions (FAQs)
What is a helideck under SOLAS?
SOLAS regulation II-2/3.26 defines a helideck as a purpose-built helicopter landing area located on a ship, including all structure, fire-fighting appliances and other equipment necessary for the safe operation of helicopters.
Regulation II-2/18.2.1 then requires every ship equipped with a helideck to comply with Regulation 18 in full.
Does a ship need a helideck to receive a helicopter?
No. SOLAS II-2/18.2.2 allows a ship without a helideck to take a helicopter on an occasional or emergency basis, by landing or by winching, using the Part C fire-fighting equipment it already carries, provided that equipment is kept close to the landing or winching area during the operation.
Ships constructed on or after 1 January 2020 that have a designated helicopter landing area must also carry the FSS Code Chapter 17 landing-area foam equipment under II-2/18.2.3.
What is the difference between a helideck, a helicopter landing area and a winching area?
A helideck (SOLAS II-2/3.26) is purpose-built for routine helicopter operations.
A helicopter landing area (II-2/3.57, added by MSC.404(96)) is designated for occasional or emergency landings and is not designed for routine operations. A winching area (II-2/3.58) is a pick-up area where personnel or stores are transferred while the helicopter hovers above the deck and never lands.
What foam discharge rate does SOLAS Regulation 18 require?
It depends on the ship’s construction date.
A helideck on a ship constructed before 1 January 2020 follows Table 18.1, set by helicopter overall length: 250 l/min below 15 m, 500 l/min from 15 m to below 24 m, and 800 l/min from 24 m to below 35 m, each for at least 5 minutes. A helideck on a ship constructed on or after 1 January 2020 follows FSS Code Chapter 17: at least 6 l/min per square metre over the D-value area, for at least 5 minutes.
Is FSS Code Chapter 17 retroactive?
No. SOLAS II-2/18.5.1.6 and 18.2.3, added by MSC.404(96), apply Chapter 17 only to ships constructed on or after 1 January 2020.
A helideck on an older ship stays on the Table 18.1 rates and the original Regulation 18.5.1 equipment list unless the flag Administration requires more.
How much dry powder and CO2 must a helideck have?
SOLAS II-2/18.5.1 requires at least two dry powder extinguishers with a total capacity of not less than 45 kg, and carbon dioxide extinguishers with a total capacity of not less than 18 kg or equivalent.
The 2009 MODU Code paragraph 9.16.4.1 repeats the 45 kg total and adds that no single dry powder unit should be under 9 kg.
What is the D-value of a helicopter?
The D-value is the largest overall dimension of the helicopter when its rotors are turning, normally from the most forward point of the main rotor tip path plane to the most rearward point of the tail rotor tip path plane.
FSS Code Chapter 17 paragraph 2.1 and CAP 437 both use this definition. CAP 437 gives the Sikorsky S-92 a D-value of 20.88 m.
What does the t number painted on a helideck mean?
It is the maximum allowable mass in tonnes, the t-value.
The 2009 MODU Code paragraph 13.5.9 specifies a two- or three-digit number followed by the letter t, given to one decimal place and rounded to the nearest 100 kg. It is a mass limit for the deck and is not a touchdown tolerance.
What does the other number on the helideck marking show?
It is the D-value of the largest helicopter the deck is certified for, in metres.
The 2009 MODU Code paragraph 13.5.7 marks it to the nearest whole number with 0.5 rounded down, so 18.5 is marked 18; its footnote treats the 19.5 m AS332L2 and EC 225 as a special case, rounded up to 20.
How large must a helideck be?
The landing area must contain a circle of at least 1D for single main rotor helicopters (2009 MODU Code 13.3.2.1; ICAO Annex 14 Volume II 3.3.4).
The MODU Code accepts 0.83D in benign climates as determined by the coastal State (13.3.3.1), and ICAO Annex 14 Volume II 3.3.8 allows two opposing 1D arcs with a minimum width of 0.83D on a bow or stern heliport with limited touchdown headings.
What are the 210-degree and 150-degree sectors?
The obstacle-free sector is an arc of at least 210 degrees in which nothing may stand above the landing surface except essential items limited in height.
The remaining 150 degrees is the limited obstacle sector: within 0.12D of the landing circle objects should not exceed 0.25 m, and over a further 0.21D they must stay below a 1:2 slope rising from 0.05D (2009 MODU Code 13.3.2.2 and 13.3.2.3; FSS Code Chapter 17 paragraphs 2.8 and 2.9).
What color are the helideck H and the touchdown circle?
The H is white, 4 m high and 3 m wide with a 0.75 m stroke.
The touchdown/positioning marking is a yellow circle 1 m wide whose inner diameter is half the D-value. The landing area perimeter is a continuous white line at least 0.3 m wide (2009 MODU Code 13.5.5, 13.5.11 and 13.5.14; CAP 437 4.13 and 4.14).
How bright must helideck perimeter lights be?
Green perimeter lights are spaced not more than 3 m apart and must give at least 30 cd from 0 to 10 degrees of elevation, 15 cd from over 10 to 20 degrees and 3 cd from over 20 to 90 degrees, with no light above 60 cd (2009 MODU Code Table 13-2; CAP 437 Appendix C).
CAP 437 treats the ring as serviceable when at least 90% of the lights work and no two adjacent lights are out.
What structural load is a helideck designed for?
CAP 437 paragraph 3.20 uses 1.5 times the maximum certificated take-off mass (MTOM) for a heavy normal landing and 2.5 times MTOM for an emergency landing in any position, and states that the emergency case usually governs.
It adds a structural response factor of 1.3, a 0.5 kN per square metre superimposed load and a lateral load of 0.5 times MTOM. SOLAS Regulation 18 itself sets no structural load factor.
What friction must a helideck surface achieve?
CAP 437 Table 3 sets minimum average friction of 0.6 on a fixed helideck and 0.65 on a moving helideck inside the touchdown/positioning circle and on its painted markings, and 0.5 outside the circle.
The surface is surveyed wet with a braked-wheel tester, annually and after remedial work, with a two-year interval allowed where every area beats the minimum by at least 0.1.
What is the Significant Heave Rate?
CAP 437 paragraph 6.6 defines the Significant Heave Rate (SHR) as twice the root mean square heave rate measured over the previous 20 minutes, reported in metres per second to one decimal place.
It is one of the parameters the helideck monitoring system reports to the pilot, alongside pitch, roll, inclination, the Motion Severity Index and the Wind Severity Index.
What do the blue, amber and red helideck motion lights mean?
Under CAP 437 paragraph 6.4, steady blue means safe to land, steady amber means land with caution because only the Motion Severity Index or Wind Severity Index is out of limits, and steady red means do not land because pitch, roll, inclination or Significant Heave Rate is out of limits.
These are the HMS repeater lights; the flashing red status light is a separate signal.
Can a helicopter land on a moving deck with no motion monitoring system?
Under CAP 437 paragraph 6.11 a moving helideck without a working helideck monitoring system is limited to the stable-deck conditions in Part C of the Helideck Limitations List: maximum pitch and roll of 1 degree and maximum Significant Heave Rate of 0.4 m/s.
CAP 437 paragraph 6.10 strongly recommends an HMS on every moving helideck.
How many fire-fighters must stand by during helicopter operations?
SOLAS II-2/18.8.3 requires fire-fighting personnel of at least two persons trained for rescue and fire-fighting duties to be immediately available whenever helicopter operations are expected, and the 2009 MODU Code paragraph 14.2.3 says the same.
CAP 437 sets no fixed head-count and sizes the team by task resource analysis.
Can the helideck fire team help with refueling?
No. SOLAS II-2/18.8.4 requires fire-fighting personnel to be present during refueling and also states that they shall not be involved with refueling activities.
The 2009 MODU Code paragraph 14.2.4 carries the same rule.
Is a helicopter hangar treated as a machinery space?
Yes, for fire protection purposes.
SOLAS II-2/18.7 requires hangar, refueling and maintenance facilities to be treated as category A machinery spaces for structural fire protection, fixed fire-extinguishing and detection systems, and enclosed hangar or refueling spaces to be mechanically ventilated with non-sparking fans.
What flash point must helicopter fuel have at sea?
CAP 437 paragraph 7.7 identifies the fuel as Jet A-1 with a flash point of at least 38 degrees C, and notes that fuel movement creates an electrostatic charge hazard.
SOLAS II-2/18.7 requires a designated tank storage area remote from accommodation and escape routes, electrical bonding of the equipment, and a pump shutdown operable from a safe remote position.
How big must a helicopter winching area be?
CAP 437 Chapter 10, which follows the ICS Guide to Helicopter/Ship Operations, specifies a maneuvering zone of at least 2D in diameter with a clear zone of at least 5 m diameter at its center.
Obstructions may not exceed 3 m in the inner maneuvering zone or 6 m in the outer zone, and the words WINCH ONLY are painted in characters at least 2 m high.
Should a helicopter land or winch if both are possible?
CAP 437 paragraph 10.1 states that, where practicable, the helicopter should always land rather than hoist.
Winching over accommodation is restricted by paragraph 10.13 to twin-engined helicopters, with the spaces below cleared, two independent access routes, doors and ports closed, and fire and rescue personnel ready but sheltered.
Do ro-ro passenger ships need a helicopter area?
Yes. SOLAS III/28.1, adopted by MSC.47(66) on 4 June 1996 and in force from 1 July 1998, requires every ro-ro passenger ship to have a helicopter pick-up area approved by the Administration.
III/28.2 as adopted requires passenger ships of 130 m in length and upwards, constructed on or after 1 July 1999, to have a helicopter landing area. SOLAS II-2/18.2.4 sends ro-ro passenger ships without helidecks to III/28.
Which edition of CAP 437 is current?
Edition 9, published in February 2023, with Amendment 01/2026 issued in January 2026, which adds Appendix L, the Master Minimum Helideck Equipment List for the UK.
CAP 437 was first published in 1981; Edition 8 dated from December 2016.
Is CAP 437 binding outside the United Kingdom?
CAP 437 is a UK Civil Aviation Authority publication, and the Helideck Certification Agency inspects helidecks against it for the UK offshore helicopter operators in UK waters.
Outside that regime, the international baseline is SOLAS II-2/18 and FSS Code Chapter 17 for ships, the 2009 MODU Code for drilling units, and ICAO Annex 14 Volume II for the aviation side, with the coastal State’s aviation authority setting any national standard.
Which chapter of the MODU Code covers helidecks?
Chapter 13, Helicopter facilities, of the 2009 MODU Code adopted by resolution A.1023(26) on 2 December 2009.
Fire-fighting is in section 9.16, helicopter communications in section 11.6 and operating procedures in section 14.2. The MODU Code is a recommendatory Assembly code that a flag State makes binding through its own law.
What training must helicopter passengers have for offshore flights?
For UK commercial air transport flights, the CAP 437 Appendix K inbound flight checklist confirms that every passenger holds the required certification, naming Category A emergency breathing system (CAT A EBS) and BOSIET or HUET training, and checks that survival suits and CAT A EBS lifejackets are worn correctly before boarding.
What training does the helideck team need?
SOLAS II-2/18.8.3 requires the fire-fighting persons to be trained for rescue and fire-fighting duties, and 18.8.5 requires on-board refresher training.
CAP 437 Appendix K paragraph K.41 states that all helideck teams should be trained to the Offshore Petroleum Industry Training Organisation (OPITO) standard or equivalent.
How quickly must helideck foam start flowing?
FSS Code Chapter 17 paragraph 3.5 requires the system to discharge foam at nominal flow and design pressure within 30 seconds of activation, and the 2009 MODU Code paragraph 9.16.4.3.3 sets the same 30-second start for foam at the minimum application rate.
Can a landing net be fitted to a helideck with a DIFFS?
CAP 437 paragraph 3.24 states that landing nets should not be fitted on a solid plate helideck where a deck integrated fire-fighting system (DIFFS) is installed.
It also limits any object on the landing surface, including tie-downs and circle and H lighting, to 25 mm in height.
Who certifies a ship's helideck?
Two parties, for two purposes. The flag Administration, or a classification society acting for it, approves the helideck structure and fire-fighting appliances under SOLAS II-2/18 as part of the ship’s statutory certification, and port State control can inspect that equipment.
The aviation side decides whether a helicopter may use the deck: in UK waters the Helideck Certification Agency inspects against CAP 437 and lists each deck’s limitations in the Helideck Limitations List.
What lighting is needed for night helideck operations in UK waters?
On the UK continental shelf, the lit touchdown/positioning circle and lit H have been mandatory for night operations since 1 April 2018, now under CAA Safety Directive SD-2022/001 of 1 June 2022, together with green perimeter lights at intervals of not more than 3 m.
CAP 437 paragraph 4.23 states that floodlighting is no longer accepted as the primary visual cue, and 4.22 asks for floodlights to be switched off during helicopter movements.
No question matches. Try a shorter or different word.
Sources
- IMO MSC.99(73), 5 December 2000. revised SOLAS Chapter II-2, including Regulation 18 Helicopter facilities imo.org
- IMO MSC.404(96), 19 May 2016. SOLAS amendments adding II-2/3.57, II-2/3.58, II-2/18.2.3 and II-2/18.5.1.6 imo.org
- IMO MSC.403(96), 19 May 2016. FSS Code Chapter 17, Helicopter facility foam firefighting appliances imo.org
- IMO A.1023(26), 2 December 2009. 2009 MODU Code, Chapter 13 Helicopter facilities and section 9.16 imo.org
- IMO MSC.47(66), 4 June 1996. revised SOLAS Chapter III, including Regulation 28 Helicopter landing and pick-up areas imo.org
- UK CAA CAP 437, Standards for Offshore Helicopter Landing Areas, Edition 9 (February 2023), Amendment 01/2026 caa.co.uk
- ICAO Annex 14 Volume II, Heliports, Fifth Edition July 2020 (consolidated copy, Swiss FOCA) bazl.admin.ch